Main and Standby: 200 Amp
30 Amp


Displaying: 1 - 4 of 4 Matching Items
4 Items
View:
Active Filters :
Part #:INTMET8015C

7 DAY ASTRONOMIC TYPE STEEL ENCLOSURE MATERIAL 5 INCH W X 3 INCH D X 7-3/4 INCH H SIZE GRAY FINISH 28 MAX. NUMBER OF OPERATIONS CSA (CANADA AND US) APPROVAL INTERIOR/EXTERIOR LIGHTING, ELECTRIC PUMP, ELECTRIC MOTOR CONTROL, SCHOOL, OFFICE, AIRPORT, STORE, HOTEL, RESTAURANT, PARK, APARTMENT APPLICATION 120/208/240/277 VAC AT 50/60 HZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 30 AMPERE AT 120/240 VAC (RESISTIVE, NO), 20 AMPERE AT 28 VDC (RESISTIVE, NO), 30 AMPERE AT 120/240 VAC (INDUCTIVE, NO), 5 AMPERE AT 120/240 VAC (TUNGSTEN, NO), 20 AMPERE AT 120 TO 277 VAC (BALLAST, NO) CURRENT RATING 1 HP AT 120 VAC (NO), 2 HP AT 240 VAC (NO) POWER RATING -40 TO 155 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE 1 CIRCUIT(S) AAA ALKALINE BATTERY RESERVE POWER MAXIMUM ON/OFF TIME 6 DAY 23 HR 59 MIN MINIMUM ON/OFF TIME 1 MIN WIRE SIZE 18 TO 10 AWG SERIES ET8000 MODEL
$ 430.48
Part #:INTMET1705C

7 DAY TYPE STEEL ENCLOSURE MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 28 MAX. NUMBER OF OPERATIONS CSA (CANADA AND US) APPROVAL INTERIOR/EXTERIOR LIGHTING, ELECTRIC PUMP, ELECTRIC MOTOR CONTROL, SCHOOL, OFFICE, AIRPORT, STORE, HOTEL, RESTAURANT, PARK, APARTMENT APPLICATION 120/208/240/277 VOLT AC AT 50/60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 30 AMP AT 120/240 VOLT AC (RESISTIVE, NO), 20 AMP AT 28 VOLT DC (RESISTIVE, NO), 30 AMP AT 120/240 VOLT AC (INDUCTIVE, NO), 5 AMP AT 120/240 VOLT AC (TUNGSTEN, NO), 20 AMP AT 120 TO 277 VOLT AC (BALLAST, NO) CURRENT RATING 1 HP AT 120 VOLT AC (NO), 2 HP AT 240 VOLT AC (NO) POWER RATING -40 TO 155 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE 1 CIRCUIT(S) AAA ALKALINE BATTERY RESERVE POWER INTERMATIC BRAND MAXIMUM ON/OFF TIME 6 DAY 23 HOUR 59 MINUTE MINIMUM ON/OFF TIME 1 MINUTE WIRE SIZE 18 TO 10 AWG ET1700 MODEL
$ 387.36
Part #:MIDWGS1202B20UL

MANUAL TYPE 15-3/4 INCH 35 INCH 7 INCH 6 AWG TO 250 KCMIL WIRE SIZE UL (CANADA AND US) APPROVAL GENERATOR APPLICATION 120/240 VAC 1-PHASE VOLTAGE RATING NEMA 3R ENCLOSURE ALUMINUM/COPPER WIRE TYPE 10000 AMPERE SHORT CIRCUIT RATING 200 AMPERE EMERGENCY CURRENT RATING 200 AMPERE MAIN CURRENT RATING CABINET SIZE 15 INCH X 35 INCH NUMBER OF POLES 2 MATERIAL G90 GALVANIZED STEEL FINISH POLYESTER POWDER COATED INCLUDES 2 INCH HUB
$ 1,744.81
Part #:MIDWU013

UNMETERED TYPE G90 GALVANIZED STEEL MATERIAL ZINC COATED FINISH 14 TO 10 AWG SOLID/STRANDED (COPPER, LINE), 14 TO 10 AWG SOLID/STRANDED (COPPER, NEUTRAL), 12 TO 8 AWG SOLID, 12 TO 2 AWG STRANDED (COPPER, GROUND) WIRE SIZE UL, CUL APPROVAL NEMA 3R ENCLOSURE 30 AMPERE CURRENT RATING 1-PHASE CIRCUIT CONFIGURATION R32U CENTER POSITION RECEPTACLE TYPE APPLICABLE STANDARD NEMA, NEC VOLTAGE RATING 120 V CABINET DIMENSION 5-3/4 INCH W X 5-3/16 INCH D X 7-1/8 INCH H MOUNTING SURFACE
$ 71.17
 
Displaying: 1 - 4 of 4 Matching Items