Part #:SIEQ2100

COMMON TRIP TYPE LOADCENTER USED ON 120/240 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 100 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) QP MODEL
$ 49.98
Part #:SIEQ115

LOADCENTER USED ON 120 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE AT 40 DEG C CURRENT RATING 1 POLE(S) QP MODEL
$ 11.84
Part #:SIEQ1515

MOLDED CASE, THERMAL MAGNETIC TYPE 1 INCH W X 2.06 INCH D X 3.12 INCH H SIZE 240 MAX. AC VOLTAGE RATING 120/240 VAC AT 60 HZ (UL) VOLTAGE RATING 10 KILOAMPERE AT 120/240 VAC (UL) INTERRUPTING RATING 15 AMPERE CURRENT RATING 1 POLE(S) SPEEDFAX[T] BRAND
$ 19.94
Part #:SIEQ1515NC

DUPLEX TYPE LOADCENTER USED ON 120 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 1 POLE(S) QT MODEL
$ 43.75
Part #:SIEQ215

COMMON TRIP TYPE LOADCENTER USED ON 120/240 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) QP MODEL
$ 23.40
Part #:MIDWGS1202B20UL

MANUAL TYPE 15-3/4 INCH 35 INCH 7 INCH 6 AWG TO 250 KCMIL WIRE SIZE UL (CANADA AND US) APPROVAL GENERATOR APPLICATION 120/240 VAC 1-PHASE VOLTAGE RATING NEMA 3R ENCLOSURE ALUMINUM/COPPER WIRE TYPE 10000 AMPERE SHORT CIRCUIT RATING 200 AMPERE EMERGENCY CURRENT RATING 200 AMPERE MAIN CURRENT RATING CABINET SIZE 15 INCH X 35 INCH NUMBER OF POLES 2 MATERIAL G90 GALVANIZED STEEL FINISH POLYESTER POWDER COATED INCLUDES 2 INCH HUB
$ 1,744.81
Part #:MIDWR101CB2

METERED RINGLESS TYPE G90 GALVANIZED STEEL MATERIAL ZINC COATED FINISH 1 AWG TO 300 KCMIL STRANDED (COPPER/ALUMINUM, LOAD CB BASE), 1 AWG TO 300 KCMIL STRANDED (COPPER/ALUMINUM, NEUTRAL LG SINGLE LUGS), 14 TO 8 AWG SOLID/14 TO 1/0 AWG STRANDED (COPPER, NEUTRAL SMALL SINGLE HOLES), 12 TO 8 AWG SOLID/12 TO 1/0 AWG STRANDED (ALUMINUM, NEUTRAL SMALL SINGLE HOLE), 14 TO 8 AWG SOLID/10 TO 4 AWG STRANDED (COPPER, NEUTRAL SIX LARGE HOLE), 6 TO 4 AWG STRANDED (ALUMINUM, NEUTRAL SIX LARGE HOLE), 14 TO 8 AWG SOLID/12 TO 8 AWG STRANDED (COPPER, NEUTRAL SMALL HOLE), 12 TO 8 AWG SOLID/STRANDED (ALUMINUM, NEUTRAL SMALL HOLE), 12 TO 8 AWG SOLID/12 TO 2 AWG STRANDED (COPPER/ALUMINUM, GROUND) WIRE SIZE UL APPROVAL NEMA 3R ENCLOSURE 100 AMPERE CURRENT RATING 1-PHASE CIRCUIT CONFIGURATION CB2100 FIRST POSITION CIRCUIT BREAKER TYPE APPLICABLE STANDARD NEMA, NEC VOLTAGE RATING 120/240 V CABINET DIMENSION 14-3/4 INCH W X 4-9/16 INCH D X 26-1/4 INCH H MOUNTING SURFACE
$ 299.99
Part #:CUTCHFN115DF

Eaton CH arc fault / ground fault circuit breaker, CH Dual Function AF/GF Breaker, 15A, Pigtail, 10 kAICkAIC
$ 93.88
 