30 Amp
20 A


Displaying: 1 - 24 of 24 Matching Items
24 Items
View:
Active Filters :
$ 33.14
Qty:
add to cart
Part #:INTMET8015C
7 DAY ASTRONOMIC TYPE STEEL ENCLOSURE MATERIAL 5 INCH W X 3 INCH D X 7-3/4 INCH H SIZE GRAY FINISH 28 MAX. NUMBER OF OPERATIONS CSA (CANADA AND US) APPROVAL INTERIOR/EXTERIOR LIGHTING, ELECTRIC PUMP, ELECTRIC MOTOR CONTROL, SCHOOL, OFFICE, AIRPORT, STORE, HOTEL, RESTAURANT, PARK, APARTMENT APPLICATION 120/208/240/277 VAC AT 50/60 HZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 30 AMPERE AT 120/240 VAC (RESISTIVE, NO), 20 AMPERE AT 28 VDC (RESISTIVE, NO), 30 AMPERE AT 120/240 VAC (INDUCTIVE, NO), 5 AMPERE AT 120/240 VAC (TUNGSTEN, NO), 20 AMPERE AT 120 TO 277 VAC (BALLAST, NO) CURRENT RATING 1 HP AT 120 VAC (NO), 2 HP AT 240 VAC (NO) POWER RATING -40 TO 155 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE 1 CIRCUIT(S) AAA ALKALINE BATTERY RESERVE POWER MAXIMUM ON/OFF TIME 6 DAY 23 HR 59 MIN MINIMUM ON/OFF TIME 1 MIN WIRE SIZE 18 TO 10 AWG SERIES ET8000 MODEL
$ 430.48
Qty:
add to cart
Part #:INTMET1705C
7 DAY TYPE STEEL ENCLOSURE MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 28 MAX. NUMBER OF OPERATIONS CSA (CANADA AND US) APPROVAL INTERIOR/EXTERIOR LIGHTING, ELECTRIC PUMP, ELECTRIC MOTOR CONTROL, SCHOOL, OFFICE, AIRPORT, STORE, HOTEL, RESTAURANT, PARK, APARTMENT APPLICATION 120/208/240/277 VOLT AC AT 50/60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 30 AMP AT 120/240 VOLT AC (RESISTIVE, NO), 20 AMP AT 28 VOLT DC (RESISTIVE, NO), 30 AMP AT 120/240 VOLT AC (INDUCTIVE, NO), 5 AMP AT 120/240 VOLT AC (TUNGSTEN, NO), 20 AMP AT 120 TO 277 VOLT AC (BALLAST, NO) CURRENT RATING 1 HP AT 120 VOLT AC (NO), 2 HP AT 240 VOLT AC (NO) POWER RATING -40 TO 155 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE 1 CIRCUIT(S) AAA ALKALINE BATTERY RESERVE POWER INTERMATIC BRAND MAXIMUM ON/OFF TIME 6 DAY 23 HOUR 59 MINUTE MINIMUM ON/OFF TIME 1 MINUTE WIRE SIZE 18 TO 10 AWG ET1700 MODEL
$ 387.36
Qty:
add to cart
Part #:CUTNL30
GROUND/NEUTRAL LUG TYPE TYPE CH LOADCENTER USED ON 1 QUANTITY
$29.00 MSRP $ 24.03
Qty:
add to cart
Part #:CUTCH2150
THERMAL MAGNETIC, COMMON TRIP TYPE CH SERIES LOADCENTER USED ON 3/0 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489, CSA APPROVAL 120/240 VAC VOLTAGE RATING PLUG-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 150 AMPERE CURRENT RATING 2 POLE(S) CH MODEL
$ 318.02
Qty:
add to cart
Part #:MILBU5168-XTL-200-KK
RINGLESS TYPE 14-1/8 INCH W X 4-1/2 INCH D X 32 INCH H SIZE 6 AWG TO 350 KCMIL (LINE) WIRE SIZE GALVANIZED STEEL ENCLOSURE MATERIAL UL APPROVAL 240 VAC VOLTAGE RATING SURFACE MOUNTING NEMA 3R ENCLOSURE 200 AMPERE CURRENT RATING 1-PHASE 3-WIRE CIRCUIT CONFIGURATION OVERHEAD/UNDERGROUND SERVICE TYPE 8 CIRCUIT(S) CLOSING PLATE HUB TYPE (1) (1/4 INCH - 1/2 INCH), (4) (1/2 INCH - 3/4 INCH), (2) (1/2 INCH - 3/4 INCH - 1 INCH), (3) (3/4 INCH - 1 INCH - 1-1/4 INCH - 1-1/2 INCH - 2 INCH), (1) (1 INCH - 1-1/4 INCH - 1-1/2 INCH - 2 INCH - 2-1/2 INCH), (1) (1-1/4 INCH - 1-1/2 INCH - 2 INCH - 2-1/2 INCH - 3 INCH) CONCENTRIC KNOCKOUT KNOCKOUT(S) 4 JAW(S) HORN BYPASS SWITCH 22 KILOAMPERE INTERRUPTING RATING CIRCUIT BREAKER MAIN DISCONNECT TYPE U5168 MODEL
$ 359.09
Qty:
add to cart
Part #:CUT3BR1836L150
MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 23 INCH H SIZE 36 MAX. NUMBER OF CIRCUITS (18) 1 INCH MAX. NUMBER OF SPACES UL APPROVAL 208 VAC STAR/120 VAC, 240 VAC VOLTAGE RATING 25 KILOAMPERE INTERRUPTING RATING 150 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1, INDOOR ENCLOSURE TYPE 3-PHASE 4-WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE TOP/BOTTOM FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL C2 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 303.51
Qty:
add to cart
Part #:SIEQ120
LOADCENTER USED ON 120 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 20 AMPERE AT 40 DEG C CURRENT RATING 1 POLE(S) QP MODEL
$ 12.49
Qty:
add to cart
Part #:MILU7021-RL-TG-KK-RGE
200 AMP O/H AND UNDERGROUND RESIDENTIAL WITH TEST TABS:
$ 91.14
Qty:
add to cart
Part #:CUTBR380
COMMON TRIP THERMAL MAGNETIC TYPE LOAD CENTER USED ON 4 TO 1/0 AWG (ALUMINUM/COPPER) WIRE SIZE 240 VAC VOLTAGE RATING PLUG ON MOUNTING 10000 AMPERE INTERRUPTING RATING 80 AMPERE CURRENT RATING 3 POLE(S) LUG TERMINAL TYPE BR MODEL
$565.00 MSRP $ 167.56
Qty:
add to cart
Part #:SIEBQ1B020
MOLDED CASE, THERMAL MAGNETIC TYPE 1 INCH W X 3 INCH D X 3-3/4 INCH H SIZE 240 MAX. AC VOLTAGE RATING 120/240 VAC AT 60 HZ VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 20 AMPERE AT 40 DEG C CURRENT RATING 1 POLE(S) LOAD LUG TERMINAL TYPE BQ FRAME TYPE BQ MODEL
$ 50.11
Qty:
add to cart
Part #:SIEQ220
COMMON TRIP TYPE LOADCENTER USED ON 120/240 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 20 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) QP MODEL
$ 19.50
Qty:
add to cart
Part #:SIEQ120AFC
120 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 20 AMPERE CURRENT RATING 1 POLES BREAKER TYPE QAF
$ 74.40
Qty:
add to cart
Part #:SIEB120
MOLDED CASE, THERMAL MAGNETIC TYPE 1 INCH W X 3 INCH D X 3-9/16 INCH H SIZE 240 MAX. AC VOLTAGE RATING 120/240 VAC AT 60 HZ (UL) VOLTAGE RATING 10 KILOAMPERE AT 120/240 VAC (UL) INTERRUPTING RATING 20 AMPERE AT 40 DEG C CURRENT RATING 1 POLE(S) LOAD LUG TERMINAL TYPE SPEEDFAX[T] BRAND
$ 14.38
Qty:
add to cart
Part #:MIDWU013
UNMETERED TYPE G90 GALVANIZED STEEL MATERIAL ZINC COATED FINISH 14 TO 10 AWG SOLID/STRANDED (COPPER, LINE), 14 TO 10 AWG SOLID/STRANDED (COPPER, NEUTRAL), 12 TO 8 AWG SOLID, 12 TO 2 AWG STRANDED (COPPER, GROUND) WIRE SIZE UL, CUL APPROVAL NEMA 3R ENCLOSURE 30 AMPERE CURRENT RATING 1-PHASE CIRCUIT CONFIGURATION R32U CENTER POSITION RECEPTACLE TYPE APPLICABLE STANDARD NEMA, NEC VOLTAGE RATING 120 V CABINET DIMENSION 5-3/4 INCH W X 5-3/16 INCH D X 7-1/8 INCH H MOUNTING SURFACE
$ 71.17
Qty:
add to cart
Part #:MILU7421-RL
RINGLESS TYPE 10 INCH W X 4-7/8 INCH D X 18-1/2 INCH H SIZE 6 AWG TO 350 KCMIL (LINE/LOAD, ALUMINUM/COPPER) WIRE SIZE UL 414 APPROVAL 600 VAC VOLTAGE RATING NEMA 3R ENCLOSURE 200 AMPERE CURRENT RATING 3 PHASE 4 WIRE CIRCUIT CONFIGURATION OVERHEAD SERVICE TYPE TRIPLEX NEUTRAL NEUTRAL TYPE SMALL OPENING HUB TYPE (1) (1/4-INCH-1/2 INCH) CONCENTRIC KNOCKOUT, (2) 3/4 INCH CONCENTRIC KNOCKOUT, (1) 2 1/2 INCH CONCENTRIC KNOCKOUT, (2) 3 INCH CONCENTRIC KNOCKOUT KNOCKOUT(S) 7 JAW(S) LEVER BYPASS SWITCH APPLICABLE STANDARD ANSI C12.7
$ 490.66
Qty:
add to cart
Part #:MILU7040-RL-TG-KK-RGE
RINGLESS TYPE 11 INCH W X 4 1/8 INCH D X 15 1/2 INCH H SIZE 6 AWG TO 350 KCMIL (LINE), 6 AWG TO 350 KCMIL (LOAD) WIRE SIZE UL APPROVAL 200 AMPERE CURRENT RATING OVERHEAD/UNDERGROUND SERVICE TYPE (1) 1/4 INCH, (1) (1/4 INCH-1/2 INCH) CONCENTRIC KNOCKOUT, (4) 2 1/2 INCH KNOCKOUT(S) 4 JAW(S) HORN BYPASS SWITCH MILBANK[R] BRAND
$ 70.50
Qty:
add to cart
$ 9.63
Qty:
add to cart
$ 23.25
Qty:
add to cart
Part #:HOMT2020
$ 29.70
Qty:
add to cart
$ 122.85
Qty:
add to cart
$ 21.14
Qty:
add to cart
Part #:CUTBAB2080
THERMAL MAGNETIC TYPE 8 TO 1/0 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489, CSA APPROVAL 120/240 VOLT AC VOLTAGE RATING BOLT-ON MOUNTING 10 KILOAMP AT 120/240 VOLT AC, 5 KILOAMP AT 24 TO 48/62.5/80 VOLT DC INTERRUPTING RATING 80 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) EXTENDED TANG LINE, BOX LUG LOAD TERMINAL TYPE CUTLER-HAMMER BRAND APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION, 120 VOLT FLUORESCENT LIGHT SWITCHING DUTY APPLICABLE STANDARD FEDERAL SPECIFICATION W-C-375B BAB MODEL
$ 105.93
Qty:
add to cart
Part #:CUTBAB3080H
THERMAL MAGNETIC TYPE 8 TO 1/0 AWG (ALUMINUM/COPPER LOAD) WIRE SIZE UL 489 CSA APPROVAL 240 VAC VOLTAGE RATING BOLT ON MOUNTING 10000 AMPERE INTERRUPTING RATING 80 AMPERE AT 40 DEG C CURRENT RATING 3 POLE(S) EXTENDED TANG LINE TERMINAL BOX LUG LOAD TERMINAL TERMINAL TYPE QUICKLAG[R] BRAND BAB MODEL
$512.00 MSRP $ 221.10
Qty:
add to cart
 
Displaying: 1 - 24 of 24 Matching Items