208 - 277 Vac
120/240v
View:
Active Filters :
- Voltage Rating: 120/240v 208 - 277 Vac 277 Vac, 125 Vdc
Part #:CUTBW2150
- THERMAL MAGNETIC MAIN TYPE LOAD CENTER USED ON 2 AWG TO 300 KCMIL (ALUMINUM/COPPER) WIRE SIZE UL 489 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 150 AMPERE CURRENT RATING 2 POLE(S)
$
105.76
Qty:
Part #:CUTBW2200
- THERMAL MAGNETIC MAIN TYPE LOAD CENTER USED ON 2 AWG TO 300 KCMIL (ALUMINUM/COPPER) WIRE SIZE UL 489 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING 2 POLE(S)
$
119.55
Qty:
Part #:INTMT104
- 24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 208 TO 277 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 5 HP AT 240 VOLT AC 1-PHASE (28 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$
136.46
Qty:
$
18.15
Qty:
$
59.51
Qty:
$
25.76
E
Qty:
$
25.63
E
Qty:
Part #:CUTCH290
- COMMON TRIP THERMAL MAGNETIC TYPE LOAD CENTER USED ON 10 TO 1/0 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489 CSA APPROVAL 120/240 VAC VOLTAGE RATING PLUG ON MOUNTING 10000 AMPERE INTERRUPTING RATING 90 AMPERE CURRENT RATING 2 POLE(S) CH MODEL
$
118.34
Qty:
Part #:CUTCH220GFT
- COMMON TRIP THERMAL MAGNETIC TYPE LOADCENTER USED ON 14 TO 6 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489 CSA APPROVAL 120/240 VAC VOLTAGE RATING PLUG ON MOUNTING 10000 AMPERE INTERRUPTING RATING 20 AMPERE CURRENT RATING 2 POLE(S) 5 MILLIAMPERE TRIP SENSITIVITY CH MODEL
Qty:
Part #:CUTCH230GFT
- COMMON TRIP THERMAL MAGNETIC TYPE LOADCENTER USED ON 14 TO 6 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489 CSA APPROVAL 120/240 VAC VOLTAGE RATING PLUG ON MOUNTING 10000 AMPERE INTERRUPTING RATING 30 AMPERE CURRENT RATING 2 POLE(S) 5 MILLIAMPERE TRIP SENSITIVITY CH MODEL
Qty:
Part #:CUTCL215
- COMMON TRIP TYPE 3 INCH LENGTH X 2 INCH WIDTH X 3 INCH HEIGHT SIZE CH SERIES LOAD CENTER USED ON 14 TO 4 AWG (COPPER/ALUMINUM) WIRE SIZE UL APPROVAL 120/240 VOLT AC VOLTAGE RATING 10 KILOAMP INTERRUPTING RATING 15 AMP CURRENT RATING 2 POLE(S) CL MODEL
$
22.85
Qty:
$
178.48
Qty:
Part #:CUTCH250GFT
- COMMON TRIP TYPE TYPE CH LOADCENTER USED ON 14 TO 6 AWG (ALUMINUM/COPPER) WIRE SIZE 120/240 VOLT AC VOLTAGE RATING PLUG-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 50 AMP CURRENT RATING 2 POLE(S) CUTLER-HAMMER BRAND SPACING SIZE (2) 3/4 INCH
$
227.08
Qty:
Part #:CUTBR150
- THERMAL MAGNETIC TYPE LOAD CENTER USED ON 14 TO 4 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489 APPROVAL 120/240 VAC VOLTAGE RATING PLUG ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 50 AMPERE CURRENT RATING 1 POLE(S) BR MODEL
$
6.96
Qty:
Part #:CUTGHB1030
- MOLDED CASE THERMAL MAGNETIC TYPE 277 MAX. AC VOLTAGE RATING 125 MAX. DC VOLTAGE RATING 480 VAC STAR/277 VAC AT 50/60 HZ 125 VDC VOLTAGE RATING 65 KILOAMPERE AT 120 VAC 14 KILOAMPERE AT 277 VAC/125 VDC INTERRUPTING RATING 30 AMPERE AT 40 DEG C CURRENT RATING 1 POLE(S) ALUMINUM PRESSURE LINE TERMINAL PRESSURE LOAD TERMINAL TERMINAL TYPE G FRAME TYPE APPLICABLE STANDARD AS 2184 BS 4752 IEC 157-1 NEMA AB-1 NF C 63-120 SABS 156 SEV 157-1 VDE 0660 MAXIMUM AC VOLTAGE RATING - UOM V MAXIMUM DC VOLTAGE RATING - UOM V GHB MODEL
$
63.69
Qty:
Part #:CUTGHB1015
- Eaton Series C complete molded case circuit breaker, G-frame, GHB, Complete breaker, Fixed thermal, Fixed magnetic trip type, Single-pole, 15 A, 277 Vac, 125 Vdc, 14 kAIC at 277 Vac, 50/60 Hz
$
69.23
Qty:
Part #:CUTGHB1020
- Eaton Series C complete molded case circuit breaker, G-frame, GHB, Complete breaker, Fixed thermal, Fixed magnetic trip type, Single-pole, 20 A, 277 Vac, 125 Vdc, 14 kAIC at 277 Vac, 50/60 Hz
$
69.23
Qty:
$
21.92
Qty:
$
55.77
Qty:
Part #:CUTQBGFT1020
- Eaton QB GFCI circuit breaker,Ground fault circuit breaker,20A,10 kAIC,Single-pole,120/240V,Non-Interchangeable,5 mA Trip sensitivity,#1410 Cu, #1210 Al,QBGF
$
130.40
Qty:
Part #:CUTCHF225
- THERMAL MAGNETIC TRIP, COMMON TRIP TYPE 1.5 INCH WIDTH X 3 INCH DEPTH X 3 INCH HEIGHT SIZE CH SERIES LOAD CENTER USED ON (1) 14 TO 8 AWG (COPPER/ALUMINUM), (2) 14 TO 10 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489, CSA APPROVAL 120/240 VOLT AC VOLTAGE RATING PLUG-ON MOUNTING 10 KILOAMP AT 120/240 VOLT AC INTERRUPTING RATING 25 AMP CURRENT RATING 2 POLE(S) CUTLER-HAMMER BRAND INCLUDES MECHANICAL TRIP FLAG APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION APPLICABLE STANDARD FEDERAL SPECIFICATION W-C375 CHF MODEL
$
26.73
Qty:
$
200.47
E
Qty:
Displaying: 1 - 24 of 24 Matching Items