5.1900 in X 14.3100 in X 45.0000 In
3.8800 in X 14.3100 in X 21.0000 In
View:
Part #:CUT3BR1224L200
- MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 27 INCH H SIZE 24 MAX. NUMBER OF CIRCUITS (12) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL C4 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
Qty:
Part #:CUTDG223NRB
- GENERAL DUTY SAFETY TYPE 3 WIRE(S) UL APPROVAL NEMA 3R ENCLOSURE 100 AMPERE CURRENT RATING 7-1/2 TO 15 HP AT 240 VAC 1 PHASE 15 TO 30 HP AT 240 VAC 3 PHASE (DUAL ELEMENT FUSE) POWER RATING 2 POLE(S) CARTRIDGE CLASS H FUSE TYPE SOLID NEUTRAL TYPE 120/240 V AC VOLTAGE RATING FUSIBLE FUSE PROVISION APPLICABLE STANDARD NEMA KS-1 GROUNDED B PHASE SYSTEM APPLICATION DG MODEL
$
172.15
Qty:
Part #:CUTDG225NRK
- GENERAL DUTY SAFETY TYPE 3 WIRE(S) UL APPROVAL NEMA 3R ENCLOSURE 400 AMPERE CURRENT RATING 50 TO 125 HP AT 240 VAC 3 PHASE 50 HP AT 250 VDC (DUAL ELEMENT FUSE) POWER RATING 2 POLE(S) CARTRIDGE CLASS H FUSE TYPE SOLID NEUTRAL TYPE 120/240 V AC VOLTAGE RATING 250 V DC VOLTAGE RATING FUSIBLE FUSE PROVISION APPLICABLE STANDARD NEMA KS-1 GROUNDED B PHASE SYSTEM APPLICATION DG MODEL
Qty:
Part #:CUTDG325NRK
- GENERAL DUTY TYPE 11.16 INCH LENGTH X 22.66 INCH WIDTH X 44.31 INCH HEIGHT SIZE GALVANIZED/PAINTED FINISH STEEL ENCLOSURE MATERIAL 4 WIRE(S) UL 98/50 APPROVAL NEMA 3R ENCLOSURE 400 AMP CURRENT RATING 50 TO 125 HP AT 240 VOLT AC 3-PHASE POWER RATING 3 POLE(S) CARTRIDGE, PLUG, CLASS H FUSE TYPE 240 VOLT AC VOLTAGE RATING 250 VOLT DC VOLTAGE RATING FUSIBLE FUSE PROVISION APPLICABLE STANDARD NEMA KS-1
$
1,381.85
Qty:
$
46.33
Qty:
Part #:CUTBRP10B100RF
- MAIN BREAKER TYPE 14-5/16 INCH W X 5-3/16 INCH D X 18-3/4 INCH H SIZE 20 MAX. NUMBER OF CIRCUITS (10) 1 INCH MAX. NUMBER OF SPACES UL APPROVAL 120/240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 100 AMPERE CURRENT RATING NEMA 3R, OUTDOOR, RAINPROOF ENCLOSURE TYPE 1-PHASE 3-WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE SPLIT NEUTRAL TYPE TOP/BOTTOM FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL BR MAIN BREAKER TYPE B2R ENCLOSURE SIZE DESIGNATION 4 TO 1/0 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC INCLUDES FEED THROUGH LUG FOR PHASE/NEUTRAL CONDUCTOR BR MODEL
$
199.82
Qty:
Displaying: 1 - 9 of 9 Matching Items