80a
40 Amp
View:
Active Filters :
- Amperage Rating: 40 Amp 80a 100 A Iec 36a, Ul 30a
Part #:INTMT101
- 24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$
113.80
Qty:
Part #:INTMT104
- 24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 208 TO 277 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 5 HP AT 240 VOLT AC 1-PHASE (28 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$
136.46
Qty:
Part #:INTMT103
- 24 HOUR TYPE STEEL MATERIAL 5-1/8 INCH WIDTH X 3-7/16 INCH DEPTH X 7-7/8 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, SIGN, POOL HEATER, BLOWER, ELECTRIC FENCE, PUMP, FAN, CONVEYER, OTHER ELECTRICAL LOAD APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE), 1000 VOLT AMP AT 120 TO 277 VOLT AC (PILOT DUTY) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA), 5 HP AT 240 VOLT AC (28 FLA) 1-PHASE POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND MAXIMUM POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT DIMENSION (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BOTTOM) INCLUDES ON/OFF TRIPPER T100 MODEL
$
133.50
Qty:
Part #:INTMT101R
- 24 HOUR TYPE STEEL MATERIAL 5-1/2 INCH WIDTH X 3-5/8 INCH DEPTH X 9-3/8 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 3R ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$
165.84
Qty:
Part #:SIEQ2100
- COMMON TRIP TYPE LOADCENTER USED ON 120/240 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 100 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) QP MODEL
$
49.98
Qty:
Part #:CUTBR380
- COMMON TRIP THERMAL MAGNETIC TYPE LOAD CENTER USED ON 4 TO 1/0 AWG (ALUMINUM/COPPER) WIRE SIZE 240 VAC VOLTAGE RATING PLUG ON MOUNTING 10000 AMPERE INTERRUPTING RATING 80 AMPERE CURRENT RATING 3 POLE(S) LUG TERMINAL TYPE BR MODEL
Qty:
Part #:CUTXBUTT4
- STANDARD TYPE 2.75 INCH LENGTH X 2.85 INCH HEIGHT SIZE GRAY COLOR 6.2 MILLIMETER BLOCK WIDTH 0.35 INCH WIRE STRIP LENGTH 26 TO 10 AWG (UL/CUL/IEC) WIRE SIZE DOUBLE TIER 2-CIRCUIT CONFIGURATION UL, CUL, CSA, CE APPROVAL 300 VOLT (UL/CUL), 800 VOLT (IEC) VOLTAGE RATING DIN RAIL MOUNTING 30 AMP (UL/CUL), 36 AMP (IEC) CURRENT RATING -40 TO 125 DEG C TEMPERATURE RATING POLYAMIDE 6.6 HOUSING MATERIAL SCREW TERMINAL TYPE IEC CONSTRUCTION STANDARD CUTLER-HAMMER BRAND XB MODEL
$
7.12
Qty:
Part #:MIDWR101CB2
- METERED RINGLESS TYPE G90 GALVANIZED STEEL MATERIAL ZINC COATED FINISH 1 AWG TO 300 KCMIL STRANDED (COPPER/ALUMINUM, LOAD CB BASE), 1 AWG TO 300 KCMIL STRANDED (COPPER/ALUMINUM, NEUTRAL LG SINGLE LUGS), 14 TO 8 AWG SOLID/14 TO 1/0 AWG STRANDED (COPPER, NEUTRAL SMALL SINGLE HOLES), 12 TO 8 AWG SOLID/12 TO 1/0 AWG STRANDED (ALUMINUM, NEUTRAL SMALL SINGLE HOLE), 14 TO 8 AWG SOLID/10 TO 4 AWG STRANDED (COPPER, NEUTRAL SIX LARGE HOLE), 6 TO 4 AWG STRANDED (ALUMINUM, NEUTRAL SIX LARGE HOLE), 14 TO 8 AWG SOLID/12 TO 8 AWG STRANDED (COPPER, NEUTRAL SMALL HOLE), 12 TO 8 AWG SOLID/STRANDED (ALUMINUM, NEUTRAL SMALL HOLE), 12 TO 8 AWG SOLID/12 TO 2 AWG STRANDED (COPPER/ALUMINUM, GROUND) WIRE SIZE UL APPROVAL NEMA 3R ENCLOSURE 100 AMPERE CURRENT RATING 1-PHASE CIRCUIT CONFIGURATION CB2100 FIRST POSITION CIRCUIT BREAKER TYPE APPLICABLE STANDARD NEMA, NEC VOLTAGE RATING 120/240 V CABINET DIMENSION 14-3/4 INCH W X 4-9/16 INCH D X 26-1/4 INCH H MOUNTING SURFACE
$
299.99
Qty:
Part #:CUTBAB2080
- THERMAL MAGNETIC TYPE 8 TO 1/0 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489, CSA APPROVAL 120/240 VOLT AC VOLTAGE RATING BOLT-ON MOUNTING 10 KILOAMP AT 120/240 VOLT AC, 5 KILOAMP AT 24 TO 48/62.5/80 VOLT DC INTERRUPTING RATING 80 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) EXTENDED TANG LINE, BOX LUG LOAD TERMINAL TYPE CUTLER-HAMMER BRAND APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION, 120 VOLT FLUORESCENT LIGHT SWITCHING DUTY APPLICABLE STANDARD FEDERAL SPECIFICATION W-C-375B BAB MODEL
$
105.93
Qty:
Part #:CUTBAB3080H
- THERMAL MAGNETIC TYPE 8 TO 1/0 AWG (ALUMINUM/COPPER LOAD) WIRE SIZE UL 489 CSA APPROVAL 240 VAC VOLTAGE RATING BOLT ON MOUNTING 10000 AMPERE INTERRUPTING RATING 80 AMPERE AT 40 DEG C CURRENT RATING 3 POLE(S) EXTENDED TANG LINE TERMINAL BOX LUG LOAD TERMINAL TERMINAL TYPE QUICKLAG[R] BRAND BAB MODEL
Qty:
Displaying: 1 - 11 of 11 Matching Items