40 Amp
20a
$
2.76
Qty:
Part #:CWDAH460C9W
- NYLON PA6 MATERIAL 0.66 INCH MIN. CABLE OUTER DIAMETER 1.5 INCH MAX. CABLE OUTER DIAMETER 4 WIRE(S) UL 498, UL 1682, UL 1686, CSA C22.2 APPROVAL 250 VAC 3-PHASE VOLTAGE RATING 60 AMPERE CURRENT RATING 3 POLE(S) CORROSION RESISTANT, DUSTTIGHT, WATERTIGHT ARROW HART[R] BRAND APPLICABLE STANDARD IEC 60309-1/60309-2 FLAMMABILITY RATING UL 94- HB (HOUSING), UL 94-V0 (CONTACT CARRIERS) POWER RATING 7-1/2 HP THREADED ENTRY 1-1/2 INCH NPT AH MODEL
$
399.60
Qty:
Part #:CWDAH460P9W
- STRAIGHT TYPE NYLON PA6 MATERIAL 0.66 INCH MIN. CABLE OUTER DIAMETER 1.5 INCH MAX. CABLE OUTER DIAMETER 4 WIRE(S) UL 1682, UL 1686, CUL, CSA C22.2 APPROVAL 250 VAC 3-PHASE VOLTAGE RATING 60 AMPERE CURRENT RATING 3 POLE(S) WATERTIGHT ARROW HART[R] BRAND APPLICABLE STANDARD IEC 60309-1/60309-2 FLAMMABILITY RATING UL 94- HB (HOUSING), UL 94-V0 (CONTACT CARRIERS) AH MODEL
$
362.60
Qty:
Part #:CWDAH460R7W
- NYLON PA6 MATERIAL 4 WIRE(S) UL 1682, UL 1686, CSA C22.2 APPROVAL 480 VAC 3-PHASE VOLTAGE RATING 60 AMPERE CURRENT RATING 3 POLE(S) WATERTIGHT ARROW HART[R] BRAND APPLICABLE STANDARD IEC 60309-1/60309-2 FLAMMABILITY RATING UL 94- HB (HOUSING), UL 94-V0 (CONTACT CARRIERS) AH MODEL
$
389.24
Qty:
Part #:INTMT101
- 24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$
119.50
Qty:
Part #:INTMT104
- 24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 208 TO 277 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 5 HP AT 240 VOLT AC 1-PHASE (28 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$
143.28
Qty:
Part #:INTMT103
- 24 HOUR TYPE STEEL MATERIAL 5-1/8 INCH WIDTH X 3-7/16 INCH DEPTH X 7-7/8 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, SIGN, POOL HEATER, BLOWER, ELECTRIC FENCE, PUMP, FAN, CONVEYER, OTHER ELECTRICAL LOAD APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE), 1000 VOLT AMP AT 120 TO 277 VOLT AC (PILOT DUTY) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA), 5 HP AT 240 VOLT AC (28 FLA) 1-PHASE POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND MAXIMUM POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT DIMENSION (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BOTTOM) INCLUDES ON/OFF TRIPPER T100 MODEL
$
140.18
Qty:
Part #:INTMT101R
- 24 HOUR TYPE STEEL MATERIAL 5-1/2 INCH WIDTH X 3-5/8 INCH DEPTH X 9-3/8 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 3R ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$
174.14
Qty:
Part #:SIEQ2100
- COMMON TRIP TYPE LOADCENTER USED ON 120/240 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 100 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) QP MODEL
$
49.98
Qty:
Part #:CUTCH220GFT
- COMMON TRIP THERMAL MAGNETIC TYPE LOADCENTER USED ON 14 TO 6 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489 CSA APPROVAL 120/240 VAC VOLTAGE RATING PLUG ON MOUNTING 10000 AMPERE INTERRUPTING RATING 20 AMPERE CURRENT RATING 2 POLE(S) 5 MILLIAMPERE TRIP SENSITIVITY CH MODEL
Qty:
Part #:CRSENR5201
- ACRYLIC PAINTED DIE-CAST COPPER-FREE ALUMINUM MATERIAL UL 894/698/1203, CSA C22.2 APPROVAL 125 VOLT AC VOLTAGE RATING CLASS I DIV 1 AND 2 GROUP C D, CLASS II DIV 1 GROUP E F G, CLASS II DIV 2 GROUP F G, CLASS III, NEMA 3, 7B/7C/7D/9E/9F/9G ENCLOSURE 20 AMP CURRENT RATING ENP MATING PLUG ARK-GARD[R] BRAND CONSTRUCTIONAL FEATURE DUSTPROOF, EXPLOSIONPROOF, IGNITIONPROOF, RAIN TIGHT APPLICATION WET LOCATION ENR MODEL
$
812.45
Qty:
Part #:MIDWR101CB2
- METERED RINGLESS TYPE G90 GALVANIZED STEEL MATERIAL ZINC COATED FINISH 1 AWG TO 300 KCMIL STRANDED (COPPER/ALUMINUM, LOAD CB BASE), 1 AWG TO 300 KCMIL STRANDED (COPPER/ALUMINUM, NEUTRAL LG SINGLE LUGS), 14 TO 8 AWG SOLID/14 TO 1/0 AWG STRANDED (COPPER, NEUTRAL SMALL SINGLE HOLES), 12 TO 8 AWG SOLID/12 TO 1/0 AWG STRANDED (ALUMINUM, NEUTRAL SMALL SINGLE HOLE), 14 TO 8 AWG SOLID/10 TO 4 AWG STRANDED (COPPER, NEUTRAL SIX LARGE HOLE), 6 TO 4 AWG STRANDED (ALUMINUM, NEUTRAL SIX LARGE HOLE), 14 TO 8 AWG SOLID/12 TO 8 AWG STRANDED (COPPER, NEUTRAL SMALL HOLE), 12 TO 8 AWG SOLID/STRANDED (ALUMINUM, NEUTRAL SMALL HOLE), 12 TO 8 AWG SOLID/12 TO 2 AWG STRANDED (COPPER/ALUMINUM, GROUND) WIRE SIZE UL APPROVAL NEMA 3R ENCLOSURE 100 AMPERE CURRENT RATING 1-PHASE CIRCUIT CONFIGURATION CB2100 FIRST POSITION CIRCUIT BREAKER TYPE APPLICABLE STANDARD NEMA, NEC VOLTAGE RATING 120/240 V CABINET DIMENSION 14-3/4 INCH W X 4-9/16 INCH D X 26-1/4 INCH H MOUNTING SURFACE
$
299.99
Qty:
$
21.92
Qty:
Part #:CUTQC1020
- THERMAL MAGNETIC TYPE 14 TO 10 AWG COPPER/ALUMINUM (LOAD) WIRE SIZE UL 489, CSA APPROVAL 120/240 VOLT AC VOLTAGE RATING CABLE-IN/CABLE-OUT MOUNTING 10000 AMP AT 120/240 VOLT AC, 5000 AMP AT 24 TO 48 VOLT DC, 3800 AMP AT 62.5 VOLT DC INTERRUPTING RATING 20 AMP AT 40 DEG C CURRENT RATING 1 POLE(S) RING TERMINAL TYPE CUTLER-HAMMER BRAND APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION, 120 VOLT FLUORESCENT LIGHT SWITCHING DUTY APPLICABLE STANDARD FEDERAL SPECIFICATION W-C-375B QC MODEL
$
60.03
Qty:
Part #:CUTQBGFT1020
- Eaton QB GFCI circuit breaker,Ground fault circuit breaker,20A,10 kAIC,Single-pole,120/240V,Non-Interchangeable,5 mA Trip sensitivity,#1410 Cu, #1210 Al,QBGF
$
130.40
Qty:
$
58.18
Qty:
$
53.99
Qty:
Displaying: 1 - 23 of 23 Matching Items