Csa Certified,Ul Listed
Ccsaus Certified, California Title 24 Compliant, Hvacr, Title Ca 20 Listed
View:
Active Filters :
- Standard: Ccsaus Certified, California Title 24 Compliant, Hvacr, Title Ca 20 Listed Csa Certified,Ul Listed Energy Star Approved, Ul Listed, Culus Listed E467698 Ul 217, Nfpa 72, (Chapter 11) the State of California Fire Marshall, Nfpa 101 (One and Two Family Dwellings), Federal Housing Authority (Fha), Housing and Urban Development (Hud)
closeout
$
9.95
Qty:
Part #:KIDI4618A
- The Kidde i4618 is an AC/DC powered, ionization smoke alarm that operates on a 120V power source with 9V battery backup. This alarm uses ionization sensing technology. Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms.
The front-loading battery door allows user to change the battery without removing the alarm from the mounting bracket making battery replacement easy and convenient. This smoke alarm is available in a 6-piece cut case with tray for easy display as well as a 6-piece bulk pack for contractors and property owners. This unit is a UL Listed product with a 5-year limited warranty. Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fire that can occur within the home.
Easy Installation
&bull Front battery pull tab allows battery activation without removing alarm from mounting bracket.
&bull Large mounting base makes mounting easier, protects surface paint from dirt and covers imperfections.
&bull Pre-stripped wiring harness with easy off cap does not require stripper tool. Tinned strands increase conductivity and wire nut grip.
Fewer Callbacks
&bull Large centrally located Test/Hush® alarm control button.
&bull Dust cover protects sensor from contaminates during construction reducing nuisance alarms.
User-Friendly Features
&bull Easy access front loading battery door.
&bull Battery backup provides protection in case of power failure.
&bull Interconnectable with up to 24 devices (of which 18 can be initiating) including smoke, CO and heat alarms. See user&rsquos guide for complete instructions.
Technical Specifications
Model
i4618
UPC
0-47871-07581-2
Power Source
120VAC (80mA Max)
Sensor
Ionization
Audio Alarm
85dB at 10ft
Temperature Range
40°F (4.4°C) to 100°F (37.8°C)
Humidity Range
Up to 85% relative humidity (RH)
Size
5.6 in diameter x 1.8 in depth
Weight
.5lbs
Interconnects
Up to 24 Kidde devices
LED
Green, receiving ac power,Red, 4 modes of operation
Warranty
5 year limited
$
12.77
Qty:
Part #:I12040
- SMOKE ALARM WITH STROBE LIGHT TYPE AC/DC IONIZATION OPERATION TYPE UL APPROVAL 85 DB AT 10 FT HORN TYPE 120 VAC 60 HZ WITH 9 V BATTERY BACKUP VOLTAGE RATING/SOURCE LED INDICATING CONDITION LED/STROBE TYPE 24 INTERCONNECTION(S) SIZE 6.5 INCH W X 13.25 INCH D X 6 INCH H
$
23.04
Qty:
Part #:INTMET8015C
- 7 DAY ASTRONOMIC TYPE STEEL ENCLOSURE MATERIAL 5 INCH W X 3 INCH D X 7-3/4 INCH H SIZE GRAY FINISH 28 MAX. NUMBER OF OPERATIONS CSA (CANADA AND US) APPROVAL INTERIOR/EXTERIOR LIGHTING, ELECTRIC PUMP, ELECTRIC MOTOR CONTROL, SCHOOL, OFFICE, AIRPORT, STORE, HOTEL, RESTAURANT, PARK, APARTMENT APPLICATION 120/208/240/277 VAC AT 50/60 HZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 30 AMPERE AT 120/240 VAC (RESISTIVE, NO), 20 AMPERE AT 28 VDC (RESISTIVE, NO), 30 AMPERE AT 120/240 VAC (INDUCTIVE, NO), 5 AMPERE AT 120/240 VAC (TUNGSTEN, NO), 20 AMPERE AT 120 TO 277 VAC (BALLAST, NO) CURRENT RATING 1 HP AT 120 VAC (NO), 2 HP AT 240 VAC (NO) POWER RATING -40 TO 155 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE 1 CIRCUIT(S) AAA ALKALINE BATTERY RESERVE POWER MAXIMUM ON/OFF TIME 6 DAY 23 HR 59 MIN MINIMUM ON/OFF TIME 1 MIN WIRE SIZE 18 TO 10 AWG SERIES ET8000 MODEL
$
430.48
Qty:
Part #:INTMET1705C
- 7 DAY TYPE STEEL ENCLOSURE MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 28 MAX. NUMBER OF OPERATIONS CSA (CANADA AND US) APPROVAL INTERIOR/EXTERIOR LIGHTING, ELECTRIC PUMP, ELECTRIC MOTOR CONTROL, SCHOOL, OFFICE, AIRPORT, STORE, HOTEL, RESTAURANT, PARK, APARTMENT APPLICATION 120/208/240/277 VOLT AC AT 50/60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 30 AMP AT 120/240 VOLT AC (RESISTIVE, NO), 20 AMP AT 28 VOLT DC (RESISTIVE, NO), 30 AMP AT 120/240 VOLT AC (INDUCTIVE, NO), 5 AMP AT 120/240 VOLT AC (TUNGSTEN, NO), 20 AMP AT 120 TO 277 VOLT AC (BALLAST, NO) CURRENT RATING 1 HP AT 120 VOLT AC (NO), 2 HP AT 240 VOLT AC (NO) POWER RATING -40 TO 155 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE 1 CIRCUIT(S) AAA ALKALINE BATTERY RESERVE POWER INTERMATIC BRAND MAXIMUM ON/OFF TIME 6 DAY 23 HOUR 59 MINUTE MINIMUM ON/OFF TIME 1 MINUTE WIRE SIZE 18 TO 10 AWG ET1700 MODEL
$
387.36
Qty:
Part #:CUTMSH5-0A
- MANUAL STARTER USED ON UL CSA APPROVAL PLUG IN MOUNTING 4 TO 4.39 AMPERE MOTOR FLA STANDARD TRIP TYPE MSH MODEL
Qty:
Part #:CUTMSH8-0A
- MANUAL STARTER USED ON UL CSA APPROVAL PLUG IN MOUNTING 6.4 TO 7.03 AMPERE MOTOR FLA STANDARD TRIP TYPE MSH MODEL
Qty:
Part #:CUTFH03
- MANUAL STARTER USED ON UL CSA APPROVAL 2 STANDARD PACKAGE M-0 (ENCLOSED) M-1 (ENCLOSED) NEMA SIZE 0.28 TO 0.29 AMPERE MOTOR FLA STANDARD TRIP TYPE FH MODEL
$
79.89
Qty:
$
58.75
E
Qty:
$
58.75
E
Qty:
$
58.75
E
Qty:
Part #:CUTAN16BN0AC
- FULL VOLTAGE, NON-REVERSING TYPE NEMA 0 SIZE 18 AMP CURRENT RATING OPEN ENCLOSURE TYPE NEMA CONSTRUCTION STANDARD 110 VOLT AC AT 50 HERTZ, 120 VOLT AC AT 60 HERTZ COIL VOLTAGE 1NO AUXILIARY CONTACT 1 HP AT 115 VOLT 1-PHASE, 2 HP AT 230 VOLT 1-PHASE, 3 HP AT 208/240 VOLT 3-PHASE, 5 HP AT 380/480/600 VOLT 3-PHASE POWER RATING/VOLTAGE BI-METALLIC AMBIENT COMPENSATED OVERLOAD RELAY OVERLOADS 1 OR 3 PHASE CUTLER-HAMMER BRAND NUMBER OF POLES 3 MOUNTING TYPE HORIZONTAL APPROVAL UL, CSA FREEDOM, AN16 MODEL
$
832.77
Qty:
Part #:CUTAN16DN0AB
- FULL VOLTAGE NON REVERSING TYPE NEMA 1 SIZE 27 AMPERE CURRENT RATING OPEN ENCLOSURE TYPE NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ 120 VAC AT 60 HZ COIL VOLTAGE 1NO RIGHT MOUNT AUXILIARY CONTACT 2 HP AT 115 V 1 PHASE 3 HP AT 230 V 1 PHASE 7-1/2 HP AT 208/240 V 3 PHASE 10 HP AT 380 V 50 HZ/480/600 V 3 PHASE POWER RATING/VOLTAGE BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS 1/3 PHASE APPROVAL UL CSA APPLICABLE STANDARD IEC 158 NEMA VDE BS NUMBER OF POLE 3 AN16 MODEL
$
885.34
Qty:
$
101.39
Qty:
Part #:CUTMSH12-9A
- MANUAL STARTER USED ON UL CSA APPROVAL PLUG IN MOUNTING 10.31 TO 11.35 AMPERE MOTOR FLA STANDARD TRIP TYPE MSH MODEL
Qty:
$
21.92
Qty:
$
21.92
Qty:
$
21.92
Qty:
$
55.77
Qty:
Part #:CUTBAB2080
- THERMAL MAGNETIC TYPE 8 TO 1/0 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489, CSA APPROVAL 120/240 VOLT AC VOLTAGE RATING BOLT-ON MOUNTING 10 KILOAMP AT 120/240 VOLT AC, 5 KILOAMP AT 24 TO 48/62.5/80 VOLT DC INTERRUPTING RATING 80 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) EXTENDED TANG LINE, BOX LUG LOAD TERMINAL TYPE CUTLER-HAMMER BRAND APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION, 120 VOLT FLUORESCENT LIGHT SWITCHING DUTY APPLICABLE STANDARD FEDERAL SPECIFICATION W-C-375B BAB MODEL
$
105.93
Qty:
Part #:CUTBAB2100
- THERMAL MAGNETIC TYPE 8 TO 1/0 AWG (ALUMINUM/COPPER LOAD) WIRE SIZE UL 489 CSA APPROVAL 120/240 VAC VOLTAGE RATING BOLT ON MOUNTING 10000 AMPERE AT 120/240 VAC 5000 AMPERE AT 24 TO 48/62.5/80 VDC INTERRUPTING RATING 100 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) EXTENDED TANG LINE TERMINAL BOX LUG LOAD TERMINAL TERMINAL TYPE QUICKLAG[R] BRAND BAB MODEL
Qty:
$
156.71
Qty:
Displaying: 1 - 24 of 25 Matching Items