Ccsaus Certified, Hvacr
Ccsaus Certified, California Title 24 Compliant, Hvacr, Title Ca 20 Listed


Displaying: 1 - 16 of 16 Matching Items
16 Items
View:
$ 112.50
Qty:
add to cart
Part #:3MO/B PLUS JUG
$ 60.00
Qty:
add to cart
$ 60.00
Qty:
add to cart
Part #:CUTGHB3020
MOLDED CASE, THERMAL MAGNETIC TYPE 3.8 INCH WIDTH X 6.6 INCH DEPTH X 4 INCH HEIGHT SIZE 480 VOLT MAX. AC VOLTAGE RATING 250 VOLT MAX. DC VOLTAGE RATING UL 489, CSA C22.2 APPROVAL 277/480 VOLT AC AT 50/60 HERTZ, 125/250 VOLT DC VOLTAGE RATING 14 KILOAMP AT 480 VOLT AC STAR/277 VOLT AC/125/250 VOLT DC INTERRUPTING RATING 20 AMP AT 40 DEG C CURRENT RATING 3 POLE(S) SCREW TYPE CLAMP LINE AND LOAD TERMINAL TYPE G FRAME TYPE CUTLER-HAMMER BRAND MOUNTING TYPE BOLT-ON APPLICATION PANELBOARD, SWITCHBOARD, MOTOR CONTROL CENTER APPLICABLE STANDARD NEMA AB1, AS 2184, BS 4752, IEC 157-1, SABS 156, SEV 157-1, VDE 0660 C, GHB MODEL
$ 269.27
Qty:
add to cart
Part #:CUTGHB3040
MOLDED CASE THERMAL MAGNETIC TYPE 3 INCH W X 2.63 INCH D X 4 INCH H SIZE 480 MAX. AC VOLTAGE RATING 250 MAX. DC VOLTAGE RATING UL 489 CSA APPROVAL 277/480 VAC AT 50/60 HZ 125/250 VDC VOLTAGE RATING 14 KILOAMPERE AT 480 VAC STAR/277 VAC/125/250 VDC INTERRUPTING RATING 40 AMPERE AT 40 DEG C CURRENT RATING 3 POLE(S) ALUMINUM PRESSURE LINE AND LOAD TERMINAL TERMINAL TYPE GHB FRAME TYPE GHB MODEL
$ 292.68
Qty:
add to cart
Part #:INTMT101
24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$ 113.80
Qty:
add to cart
Part #:INTMT104
24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 208 TO 277 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 5 HP AT 240 VOLT AC 1-PHASE (28 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$ 136.46
Qty:
add to cart
Part #:INTMT103
24 HOUR TYPE STEEL MATERIAL 5-1/8 INCH WIDTH X 3-7/16 INCH DEPTH X 7-7/8 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, SIGN, POOL HEATER, BLOWER, ELECTRIC FENCE, PUMP, FAN, CONVEYER, OTHER ELECTRICAL LOAD APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE), 1000 VOLT AMP AT 120 TO 277 VOLT AC (PILOT DUTY) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA), 5 HP AT 240 VOLT AC (28 FLA) 1-PHASE POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND MAXIMUM POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT DIMENSION (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BOTTOM) INCLUDES ON/OFF TRIPPER T100 MODEL
$ 133.50
Qty:
add to cart
Part #:INTMT101R
24 HOUR TYPE STEEL MATERIAL 5-1/2 INCH WIDTH X 3-5/8 INCH DEPTH X 9-3/8 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 3R ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$ 165.84
Qty:
add to cart
Part #:INTMET8015C
7 DAY ASTRONOMIC TYPE STEEL ENCLOSURE MATERIAL 5 INCH W X 3 INCH D X 7-3/4 INCH H SIZE GRAY FINISH 28 MAX. NUMBER OF OPERATIONS CSA (CANADA AND US) APPROVAL INTERIOR/EXTERIOR LIGHTING, ELECTRIC PUMP, ELECTRIC MOTOR CONTROL, SCHOOL, OFFICE, AIRPORT, STORE, HOTEL, RESTAURANT, PARK, APARTMENT APPLICATION 120/208/240/277 VAC AT 50/60 HZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 30 AMPERE AT 120/240 VAC (RESISTIVE, NO), 20 AMPERE AT 28 VDC (RESISTIVE, NO), 30 AMPERE AT 120/240 VAC (INDUCTIVE, NO), 5 AMPERE AT 120/240 VAC (TUNGSTEN, NO), 20 AMPERE AT 120 TO 277 VAC (BALLAST, NO) CURRENT RATING 1 HP AT 120 VAC (NO), 2 HP AT 240 VAC (NO) POWER RATING -40 TO 155 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE 1 CIRCUIT(S) AAA ALKALINE BATTERY RESERVE POWER MAXIMUM ON/OFF TIME 6 DAY 23 HR 59 MIN MINIMUM ON/OFF TIME 1 MIN WIRE SIZE 18 TO 10 AWG SERIES ET8000 MODEL
$ 430.48
Qty:
add to cart
Part #:INTMET1705C
7 DAY TYPE STEEL ENCLOSURE MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 28 MAX. NUMBER OF OPERATIONS CSA (CANADA AND US) APPROVAL INTERIOR/EXTERIOR LIGHTING, ELECTRIC PUMP, ELECTRIC MOTOR CONTROL, SCHOOL, OFFICE, AIRPORT, STORE, HOTEL, RESTAURANT, PARK, APARTMENT APPLICATION 120/208/240/277 VOLT AC AT 50/60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 30 AMP AT 120/240 VOLT AC (RESISTIVE, NO), 20 AMP AT 28 VOLT DC (RESISTIVE, NO), 30 AMP AT 120/240 VOLT AC (INDUCTIVE, NO), 5 AMP AT 120/240 VOLT AC (TUNGSTEN, NO), 20 AMP AT 120 TO 277 VOLT AC (BALLAST, NO) CURRENT RATING 1 HP AT 120 VOLT AC (NO), 2 HP AT 240 VOLT AC (NO) POWER RATING -40 TO 155 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE 1 CIRCUIT(S) AAA ALKALINE BATTERY RESERVE POWER INTERMATIC BRAND MAXIMUM ON/OFF TIME 6 DAY 23 HOUR 59 MINUTE MINIMUM ON/OFF TIME 1 MINUTE WIRE SIZE 18 TO 10 AWG ET1700 MODEL
$ 387.36
Qty:
add to cart
Part #:CUTGHB1030
MOLDED CASE THERMAL MAGNETIC TYPE 277 MAX. AC VOLTAGE RATING 125 MAX. DC VOLTAGE RATING 480 VAC STAR/277 VAC AT 50/60 HZ 125 VDC VOLTAGE RATING 65 KILOAMPERE AT 120 VAC 14 KILOAMPERE AT 277 VAC/125 VDC INTERRUPTING RATING 30 AMPERE AT 40 DEG C CURRENT RATING 1 POLE(S) ALUMINUM PRESSURE LINE TERMINAL PRESSURE LOAD TERMINAL TERMINAL TYPE G FRAME TYPE APPLICABLE STANDARD AS 2184 BS 4752 IEC 157-1 NEMA AB-1 NF C 63-120 SABS 156 SEV 157-1 VDE 0660 MAXIMUM AC VOLTAGE RATING - UOM V MAXIMUM DC VOLTAGE RATING - UOM V GHB MODEL
$ 63.69
Qty:
add to cart
Part #:CUTGHB1015
Eaton Series C complete molded case circuit breaker, G-frame, GHB, Complete breaker, Fixed thermal, Fixed magnetic trip type, Single-pole, 15 A, 277 Vac, 125 Vdc, 14 kAIC at 277 Vac, 50/60 Hz
$ 69.23
Qty:
add to cart
Part #:CUTGHB1020
Eaton Series C complete molded case circuit breaker, G-frame, GHB, Complete breaker, Fixed thermal, Fixed magnetic trip type, Single-pole, 20 A, 277 Vac, 125 Vdc, 14 kAIC at 277 Vac, 50/60 Hz
$ 69.23
Qty:
add to cart
Part #:CUTGHB2030
MOLDED CASE THERMAL MAGNETIC TYPE 480 MAX. AC VOLTAGE RATING 250 MAX. DC VOLTAGE RATING UL 489 CSA APPROVAL 277/480 VAC AT 50/60 HZ 125/250 VDC VOLTAGE RATING 14 KILOAMPERE AT 480 VAC STAR/277 VAC/125/250 VDC INTERRUPTING RATING 30 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) ALUMINUM PRESSURE LINE AND LOAD TERMINAL TERMINAL TYPE GHB FRAME TYPE GHB MODEL
$412.00 MSRP $ 152.57
Qty:
add to cart
$ 269.27
Qty:
add to cart
 
Displaying: 1 - 16 of 16 Matching Items