For Emt Conduit
Circuit Protection
View:
Active Filters :
Part #:EMTTER125
- PRESS-ON, PUSH-ON TYPE PLASTIC MATERIAL 0.614 INCH EMT CONDUIT USED ON UL, CSA APPROVAL 1.64 INCH DIAMETER 100 PER PACK STANDARD PACKAGE 1-1/4 INCH TRADE SIZE INSULATED THROAT TYPE COLOR WHITE APPLICATION POWER, CABLE TV, COMPUTER DATA LINE, TELEPHONE/MODEM, A/V CABLE, ALARM SYSTEM, SECURITY SYSTEM
$
1.00
Part #:EMTTER150
- PRESS-ON, PUSH-ON TYPE PLASTIC MATERIAL 0.63 INCH EMT CONDUIT USED ON UL, CSA APPROVAL 1.915 INCH DIAMETER 100 PER PACK STANDARD PACKAGE 1-1/2 INCH TRADE SIZE INSULATED THROAT TYPE COLOR WHITE APPLICATION POWER, CABLE TV, COMPUTER DATA LINE, TELEPHONE/MODEM, A/V CABLE, ALARM SYSTEM, SECURITY SYSTEM
$
1.35
Part #:CWDAHDS30
- NON-FUSED TYPE 8.75 INCH L X 5 INCH W X 5.68 INCH H SIZE PADLOCK HANDLE TYPE 3 PHASE(S) UL (CANADA AND US) APPROVAL CONTROL CIRCUIT APPLICATION 600 VAC VOLTAGE RATING NEMA 4X, 12, IP67 ENCLOSURE 30 AMPERE CURRENT RATING 3 POLE(S) 14 TO 10 AWG CONDUCTOR SIZE ROHS COMPLIANT MATERIAL THERMOPLASTIC
$
250.46
Qty:
$
400.94
Qty:
Part #:CWDAH7810UD
- 3-PHASE TYPE 1.69 INCH WIDTH X 1.75 INCH DEPTH X 3.28 INCH HEIGHT SIZE 3-POLE, 1-THROW OPERATION TYPE UL (CANADA AND US) APPROVAL 600 VOLT AC VOLTAGE RATING NEMA 1/3R/4X ENCLOSURE 30 AMP CURRENT RATING 7.5 HP AT 240 V 3 HP AT 120 V 15 HP AT 600 V 15 HP AT 480 V ROHS COMPLIANT WIRE SIZE 10 AWG APPLICATION INDUSTRIAL WIRING POSITION FRONT CONSTRUCTIONAL FEATURE CORROSION RESISTANCE
$
148.14
Qty:
$
144.00
Qty:
$
108.10
Qty:
Part #:CWDAH6810U
- 1-PHASE TYPE GLASS-FILLED NYLON MATERIAL 1.69 INCH W X 1.75 INCH D X 3.81 INCH H SIZE DPST OPERATION TYPE UL (CANADA AND US) APPROVAL 600 VAC VOLTAGE RATING 30 AMPERE CURRENT RATING 5 HP HP AT 240 V 2 HP HP AT 120 V 7.5 HP HP AT 600 V 7.5 HP HP AT 480 V ARROW HART[R] BRAND TERMINATION STYLE FRONT WIRED SCREW WIRE SIZE 10 AWG ROHS COMPLIANT NAFTA COMPLIANT
$
98.74
Qty:
Part #:MILBU5168-XTL-200-KK
- RINGLESS TYPE 14-1/8 INCH W X 4-1/2 INCH D X 32 INCH H SIZE 6 AWG TO 350 KCMIL (LINE) WIRE SIZE GALVANIZED STEEL ENCLOSURE MATERIAL UL APPROVAL 240 VAC VOLTAGE RATING SURFACE MOUNTING NEMA 3R ENCLOSURE 200 AMPERE CURRENT RATING 1-PHASE 3-WIRE CIRCUIT CONFIGURATION OVERHEAD/UNDERGROUND SERVICE TYPE 8 CIRCUIT(S) CLOSING PLATE HUB TYPE (1) (1/4 INCH - 1/2 INCH), (4) (1/2 INCH - 3/4 INCH), (2) (1/2 INCH - 3/4 INCH - 1 INCH), (3) (3/4 INCH - 1 INCH - 1-1/4 INCH - 1-1/2 INCH - 2 INCH), (1) (1 INCH - 1-1/4 INCH - 1-1/2 INCH - 2 INCH - 2-1/2 INCH), (1) (1-1/4 INCH - 1-1/2 INCH - 2 INCH - 2-1/2 INCH - 3 INCH) CONCENTRIC KNOCKOUT KNOCKOUT(S) 4 JAW(S) HORN BYPASS SWITCH 22 KILOAMPERE INTERRUPTING RATING CIRCUIT BREAKER MAIN DISCONNECT TYPE U5168 MODEL
$
356.30
Part #:SIEQ120
- LOADCENTER USED ON 120 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 20 AMPERE AT 40 DEG C CURRENT RATING 1 POLE(S) QP MODEL
$
11.47
Part #:SIEQ2100
- COMMON TRIP TYPE LOADCENTER USED ON 120/240 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 100 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) QP MODEL
$
49.73
Part #:CUTCH220GFT
- COMMON TRIP THERMAL MAGNETIC TYPE LOADCENTER USED ON 14 TO 6 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489 CSA APPROVAL 120/240 VAC VOLTAGE RATING PLUG ON MOUNTING 10000 AMPERE INTERRUPTING RATING 20 AMPERE CURRENT RATING 2 POLE(S) 5 MILLIAMPERE TRIP SENSITIVITY CH MODEL
Qty:
Part #:CUTCH230GFT
- COMMON TRIP THERMAL MAGNETIC TYPE LOADCENTER USED ON 14 TO 6 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489 CSA APPROVAL 120/240 VAC VOLTAGE RATING PLUG ON MOUNTING 10000 AMPERE INTERRUPTING RATING 30 AMPERE CURRENT RATING 2 POLE(S) 5 MILLIAMPERE TRIP SENSITIVITY CH MODEL
Qty:
Part #:SIEBQ1B020
- MOLDED CASE, THERMAL MAGNETIC TYPE 1 INCH W X 3 INCH D X 3-3/4 INCH H SIZE 240 MAX. AC VOLTAGE RATING 120/240 VAC AT 60 HZ VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 20 AMPERE AT 40 DEG C CURRENT RATING 1 POLE(S) LOAD LUG TERMINAL TYPE BQ FRAME TYPE BQ MODEL
$
52.26
Part #:SIEQ115
- LOADCENTER USED ON 120 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE AT 40 DEG C CURRENT RATING 1 POLE(S) QP MODEL
$
11.47
Part #:SIEQ1515
- MOLDED CASE, THERMAL MAGNETIC TYPE 1 INCH W X 2.06 INCH D X 3.12 INCH H SIZE 240 MAX. AC VOLTAGE RATING 120/240 VAC AT 60 HZ (UL) VOLTAGE RATING 10 KILOAMPERE AT 120/240 VAC (UL) INTERRUPTING RATING 15 AMPERE CURRENT RATING 1 POLE(S) SPEEDFAX[T] BRAND
$
19.94
Qty:
Part #:SIEQ215
- COMMON TRIP TYPE LOADCENTER USED ON 120/240 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 15 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) QP MODEL
$
23.40
Part #:SIEQ220
- COMMON TRIP TYPE LOADCENTER USED ON 120/240 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 20 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) QP MODEL
$
19.50
Part #:SIEQ230
- COMMON TRIP TYPE LOADCENTER USED ON 120/240 VAC VOLTAGE RATING PLUG IN MOUNTING 10 KILOAMPERE INTERRUPTING RATING 30 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) QP MODEL
$
28.08
Displaying: 1 - 24 of 42 Matching Items