Ul 217, Nfpa 72, (Chapter 11) the State of California Fire Marshall, Nfpa 101 (One and Two Family Dwellings), Federal Housing Authority (Fha), Housing and Urban Development (Hud)
Csa File Number: 72632; Ul Specifications: Ul 486a-B; Ul File Number: E9998
View:
Active Filters :
- Standard: Csa File Number: 72632; Ul Specifications: Ul 486a-B; Ul File Number: E9998 Ul 217, Nfpa 72, (Chapter 11) the State of California Fire Marshall, Nfpa 101 (One and Two Family Dwellings), Federal Housing Authority (Fha), Housing and Urban Development (Hud) Ul 231,Ul Listed File E163588 Ul Ce Iec and Csa
$
112.50
Qty:
$
60.00
Qty:
$
60.00
Qty:
Part #:KIDI4618A
- The Kidde i4618 is an AC/DC powered, ionization smoke alarm that operates on a 120V power source with 9V battery backup. This alarm uses ionization sensing technology. Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms.
The front-loading battery door allows user to change the battery without removing the alarm from the mounting bracket making battery replacement easy and convenient. This smoke alarm is available in a 6-piece cut case with tray for easy display as well as a 6-piece bulk pack for contractors and property owners. This unit is a UL Listed product with a 5-year limited warranty. Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fire that can occur within the home.
Easy Installation
&bull Front battery pull tab allows battery activation without removing alarm from mounting bracket.
&bull Large mounting base makes mounting easier, protects surface paint from dirt and covers imperfections.
&bull Pre-stripped wiring harness with easy off cap does not require stripper tool. Tinned strands increase conductivity and wire nut grip.
Fewer Callbacks
&bull Large centrally located Test/Hush® alarm control button.
&bull Dust cover protects sensor from contaminates during construction reducing nuisance alarms.
User-Friendly Features
&bull Easy access front loading battery door.
&bull Battery backup provides protection in case of power failure.
&bull Interconnectable with up to 24 devices (of which 18 can be initiating) including smoke, CO and heat alarms. See user&rsquos guide for complete instructions.
Technical Specifications
Model
i4618
UPC
0-47871-07581-2
Power Source
120VAC (80mA Max)
Sensor
Ionization
Audio Alarm
85dB at 10ft
Temperature Range
40°F (4.4°C) to 100°F (37.8°C)
Humidity Range
Up to 85% relative humidity (RH)
Size
5.6 in diameter x 1.8 in depth
Weight
.5lbs
Interconnects
Up to 24 Kidde devices
LED
Green, receiving ac power,Red, 4 modes of operation
Warranty
5 year limited
$
12.77
Qty:
Part #:I12040
- SMOKE ALARM WITH STROBE LIGHT TYPE AC/DC IONIZATION OPERATION TYPE UL APPROVAL 85 DB AT 10 FT HORN TYPE 120 VAC 60 HZ WITH 9 V BATTERY BACKUP VOLTAGE RATING/SOURCE LED INDICATING CONDITION LED/STROBE TYPE 24 INTERCONNECTION(S) SIZE 6.5 INCH W X 13.25 INCH D X 6 INCH H
$
23.04
Qty:
Part #:ILSAK-4
- ELECTRO-TIN PLATED HEAT TREATED ALUMINUM ALLOY MATERIAL 8 AWG SOLID MIN. RUN CONDUCTOR SIZE 4 AWG STRANDED MAX. RUN CONDUCTOR SIZE 10 AWG SOLID MIN. TAP CONDUCTOR SIZE 4 AWG STRANDED MAX. TAP CONDUCTOR SIZE HEX HEAD SPLIT BOLT WITH SPACER BAR INSTALLATION ALUMINUM/COPPER CONDUCTOR MATERIAL UL 670B, CSA APPROVAL 2000 V VOLTAGE RATING SIZE 0.81 INCH W X 1.38 INCH H TORQUE RATING 165 LB-INCH TEMPERATURE RATING 90 DEG C AK MODEL
$
5.17
Qty:
Part #:AK-2
- ELECTRO-TIN PLATED HEAT TREATED ALUMINUM ALLOY MATERIAL 6 AWG STRANDED (COMPACT) MIN. RUN CONDUCTOR SIZE 2 AWG STRANDED (COMPACT) MAX. RUN CONDUCTOR SIZE 8 AWG STRANDED MIN. TAP CONDUCTOR SIZE 2 AWG STRANDED MAX. TAP CONDUCTOR SIZE HEX HEAD SPLIT BOLT WITH SPACER BAR INSTALLATION ALUMINUM/COPPER CONDUCTOR MATERIAL UL 670B, CSA APPROVAL 2000 V VOLTAGE RATING SIZE 0.94 INCH W X 1.58 INCH H TORQUE RATING 275 LB-INCH TEMPERATURE RATING 90 DEG C AK MODEL
$
7.10
Qty:
Part #:ILSAK-1/0
- ELECTRO-TIN PLATED HEAT TREATED ALUMINUM ALLOY MATERIAL 2 AWG STRANDED (COMPACT) MIN. RUN CONDUCTOR SIZE 1/0 AWG STRANDED (COMPACT) MAX. RUN CONDUCTOR SIZE 8 AWG STRANDED MIN. TAP CONDUCTOR SIZE 1/0 AWG STRANDED MAX. TAP CONDUCTOR SIZE HEX HEAD SPLIT BOLT WITH SPACER BAR INSTALLATION ALUMINUM/COPPER CONDUCTOR MATERIAL UL 670B, CSA APPROVAL 2000 V VOLTAGE RATING SIZE 1 INCH W X 1.92 INCH H TORQUE RATING 385 LB-INCH TEMPERATURE RATING 90 DEG C AK MODEL
$
10.53
Qty:
Part #:CUTCHU1S
- UNMETERED TYPE GALVANIZED STEEL MATERIAL BAKED ON POLYESTER POWDER COATED FINISH 8 TO 2/0 AWG WIRE SIZE UL 231 APPROVAL NEMA 3R ENCLOSURE 50 AMPERE CURRENT RATING 3-POLE, 4-WIRE CIRCUIT CONFIGURATION 14-50R, 125/250 V 50 AMPERE CENTER POSITION RECEPTACLE TYPE NUMBER OF CIRCUITS 4 FEED TYPE TOP CHU MODEL
$
83.57
Qty:
Part #:CUTCHU4S
- UNMETERED TYPE GALVANIZED STEEL MATERIAL BAKED ON POLYESTER POWDER COATED FINISH 8 TO 2/0 AWG WIRE SIZE UL 231 APPROVAL NEMA 3R ENCLOSURE 30 AMPERE CURRENT RATING TT-30R, 125 V 30 AMPERE CENTER POSITION RECEPTACLE TYPE NUMBER OF CIRCUITS 4 FEED TYPE TOP CHU MODEL
$
81.49
Qty:
Displaying: 1 - 10 of 10 Matching Items