Csa File Number: Lr-29601; Ul Specifications: Ul 486a-B; Ul File Number: E6207
Csa File Number: Lr-29601; Ul File Number: E6207; Ul Specifications: Ul 486a-B
View:
$
2,052.06
Qty:
Part #:ILSPBTD-3-250
- 6 AWG MIN. CONDUCTOR SIZE 250 KCMIL MAX. CONDUCTOR SIZE COPPER/ALUMINUM CONDUCTOR MATERIAL UL 453G, UL 486A/B, CSA APPROVAL 600 V VOLTAGE RATING HIGH DIELECTRIC STRENGTH PLASTISOL INSULATED BODY MATERIAL 3 PORT(S) 2 SIDE ENTRY CABLE ENTRY NIMBUS[R] BRAND ROHS COMPLIANT SIZE 3.07 INCH L X 2.13 INCH W X 2.17 INCH H SCREW SIZE 5/16 INCH HEX CURRENT RATING 290 AMPERE TEMPERATURE RATING 90 DEG C, -45 DEG C (COLD) PBTD MODEL
$
15.14
Qty:
Part #:CUTBR612L125RP
- MAIN LUG TYPE 11 INCH W X 3-9/16 INCH D X 13 INCH H SIZE 12 MAX. NUMBER OF CIRCUITS (6) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING NEMA 3R OUTDOOR RAIN PROOF ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL 7R ENCLOSURE SIZE DESIGNATION 14 TO 1 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$
93.52
Qty:
$
73.37
Qty:
Part #:CUTBR612L125SP
- MAIN LUG TYPE 11 INCH W X 3-9/16 INCH D X 13 INCH H SIZE 12 MAX. NUMBER OF CIRCUITS (6) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING SURFACE WITHOUT DOOR COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL 7 ENCLOSURE SIZE DESIGNATION 14 TO 1 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$
58.49
Qty:
$
46.33
Qty:
Part #:CUT3BR4242B200R
- MAIN BREAKER TYPE 14-5/16 INCH W X 5-3/16 INCH D X 45 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING NEMA 3R OUTDOOR RAIN PROOF ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL CC MAIN BREAKER TYPE L2R ENCLOSURE SIZE DESIGNATION 1 AWG TO 250 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$
1,631.77
Qty:
Part #:CUTBRP10B100RF
- MAIN BREAKER TYPE 14-5/16 INCH W X 5-3/16 INCH D X 18-3/4 INCH H SIZE 20 MAX. NUMBER OF CIRCUITS (10) 1 INCH MAX. NUMBER OF SPACES UL APPROVAL 120/240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 100 AMPERE CURRENT RATING NEMA 3R, OUTDOOR, RAINPROOF ENCLOSURE TYPE 1-PHASE 3-WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE SPLIT NEUTRAL TYPE TOP/BOTTOM FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL BR MAIN BREAKER TYPE B2R ENCLOSURE SIZE DESIGNATION 4 TO 1/0 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC INCLUDES FEED THROUGH LUG FOR PHASE/NEUTRAL CONDUCTOR BR MODEL
$
199.82
Qty:
$
196.39
Qty:
$
383.71
Qty:
$
221.01
Qty:
$
237.46
Qty:
Qty:
$
190.41
Qty:
$
263.82
Qty:
$
183.53
Qty:
$
162.00
Qty:
$
180.45
Qty:
Displaying: 25 - 48 of 48 Matching Items