Part #:CUT3BR4242B200R
MAIN BREAKER TYPE 14-5/16 INCH W X 5-3/16 INCH D X 45 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING NEMA 3R OUTDOOR RAIN PROOF ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL CC MAIN BREAKER TYPE L2R ENCLOSURE SIZE DESIGNATION 1 AWG TO 250 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 1,631.77
Qty:
add to cart
Part #:CUTGHB1030
MOLDED CASE THERMAL MAGNETIC TYPE 277 MAX. AC VOLTAGE RATING 125 MAX. DC VOLTAGE RATING 480 VAC STAR/277 VAC AT 50/60 HZ 125 VDC VOLTAGE RATING 65 KILOAMPERE AT 120 VAC 14 KILOAMPERE AT 277 VAC/125 VDC INTERRUPTING RATING 30 AMPERE AT 40 DEG C CURRENT RATING 1 POLE(S) ALUMINUM PRESSURE LINE TERMINAL PRESSURE LOAD TERMINAL TERMINAL TYPE G FRAME TYPE APPLICABLE STANDARD AS 2184 BS 4752 IEC 157-1 NEMA AB-1 NF C 63-120 SABS 156 SEV 157-1 VDE 0660 MAXIMUM AC VOLTAGE RATING - UOM V MAXIMUM DC VOLTAGE RATING - UOM V GHB MODEL
$ 63.69
Qty:
add to cart
Part #:CUTGHB1015
Eaton Series C complete molded case circuit breaker, G-frame, GHB, Complete breaker, Fixed thermal, Fixed magnetic trip type, Single-pole, 15 A, 277 Vac, 125 Vdc, 14 kAIC at 277 Vac, 50/60 Hz
$ 69.23
Qty:
add to cart
Part #:CUTGHB1020
Eaton Series C complete molded case circuit breaker, G-frame, GHB, Complete breaker, Fixed thermal, Fixed magnetic trip type, Single-pole, 20 A, 277 Vac, 125 Vdc, 14 kAIC at 277 Vac, 50/60 Hz
$ 69.23
Qty:
add to cart
Part #:CUTBRP40B200R
$ 609.91
Qty:
add to cart
Part #:CUT3BR4242B200
MAIN BREAKER TYPE 14-5/16 INCH W X 3-7/8 INCH D X 45 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL CC MAIN BREAKER TYPE L2 ENCLOSURE SIZE DESIGNATION 1 AWG TO 250 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 803.50
Qty:
add to cart
Part #:CUT3BR3042L200
MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 34-1/8 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (30) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL G1 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL