Features: Tubular Construction With Staked Robertson Head Screws; Concrete-Tight When Taped; Meets Ul514b, Fed Spec W-F-408e, Nema Fb-1; Ul and Cul Listed for Emt, Imc and Rigid Conduit; Includes: Staked Robertson Head Set Screw; Master Quantity: 100; Cons
EMT Fittings
View:
Active Filters :
- Main Category: EMT Fittings
- Special Features: Features: Tubular Construction With Staked Robertson Head Screws; Concrete-Tight When Taped; Meets Ul514b, Fed Spec W-F-408e, Nema Fb-1; Ul and Cul Listed for Emt, Imc and Rigid Conduit; Includes: Staked Robertson Head Set Screw; Master Quantity: 100; Cons Features: Tubular Construction With Staked Robertson Head Screws; Concrete-Tight When Taped; Meets Ul514b, Fed Spec W-F-408e, Nema Fb-1; Ul and Cul Listed for Emt, Imc and Rigid Conduit; Includes: Staked Robertson Head Set Screw; Master Quantity: 125; Cons Neoprene Gasket. Threaded Interior for Use With Rigid/imc Conduit, Set Screws for Use With Emt Conduit Tubular Construction With Staked Robertson Head Screws; Concrete-Tight When Taped; 1-1/4 to 4 in Furnished With 2 Set Screws; Connects Emt Conduit to Box or Enclosure
Part #:STSSCN114
- SET SCREW TYPE STEEL MATERIAL IMC/RIGID/EMT CONDUIT USED ON UL 514B, CUL APPROVAL 25 STANDARD PACKAGE 1-1/4 INCH TRADE SIZE CONCRETE-TIGHT NON-INSULATED THROAT TYPE ROHS COMPLIANT APPLICABLE STANDARD FEDERAL SPECIFICATION W-F-408E, NEMA FB1 INCLUDES (2) SET SCREW
$
1.39
Qty:
Part #:STSSCN100
- SET SCREW TYPE STEEL MATERIAL IMC/RIGID/EMT CONDUIT USED ON UL 514B, CUL APPROVAL 100 STANDARD PACKAGE 1 INCH TRADE SIZE CONCRETE-TIGHT NON-INSULATED THROAT TYPE ROHS COMPLIANT APPLICABLE STANDARD FEDERAL SPECIFICATION W-F-408E, NEMA FB1
$
0.69
Qty:
Part #:STSSCN200
- SET SCREW TYPE STEEL MATERIAL IMC/RIGID/EMT CONDUIT USED ON UL 514B, CUL APPROVAL 10 STANDARD PACKAGE 2 INCH TRADE SIZE CONCRETE-TIGHT NON-INSULATED THROAT TYPE ROHS COMPLIANT APPLICABLE STANDARD FEDERAL SPECIFICATION W-F-408E, NEMA FB1 INCLUDES (2) SET SCREW
$
2.56
Qty:
Part #:STSSCN112
- SET SCREW TYPE STEEL MATERIAL IMC/RIGID/EMT CONDUIT USED ON UL 514B, CUL APPROVAL 10 STANDARD PACKAGE 1-1/2 INCH TRADE SIZE CONCRETE-TIGHT NON-INSULATED THROAT TYPE ROHS COMPLIANT APPLICABLE STANDARD FEDERAL SPECIFICATION W-F-408E, NEMA FB1 INCLUDES (2) SET SCREW
$
2.02
Qty:
Part #:STSSCN034
- SET SCREW TYPE STEEL MATERIAL IMC/RIGID/EMT CONDUIT USED ON UL 514B, CUL APPROVAL 125 STANDARD PACKAGE 3/4 INCH TRADE SIZE CONCRETE-TIGHT NON-INSULATED THROAT TYPE ROHS COMPLIANT APPLICABLE STANDARD FEDERAL SPECIFICATION W-F-408E, NEMA FB1
$
0.80
Qty:
Part #:STSSCN212
- SET SCREW TYPE STEEL MATERIAL IMC/RIGID/EMT CONDUIT USED ON UL 514B, CUL APPROVAL 8 STANDARD PACKAGE 2-1/2 INCH TRADE SIZE CONCRETE-TIGHT NON-INSULATED THROAT TYPE ROHS COMPLIANT APPLICABLE STANDARD FEDERAL SPECIFICATION W-F-408E, NEMA FB1 INCLUDES (2) SET SCREW
$
7.84
Qty:
Part #:STSSCN300
- SET SCREW TYPE STEEL MATERIAL IMC/RIGID/EMT CONDUIT USED ON UL 514B, CUL APPROVAL 4 STANDARD PACKAGE 3 INCH TRADE SIZE CONCRETE-TIGHT NON-INSULATED THROAT TYPE ROHS COMPLIANT APPLICABLE STANDARD FEDERAL SPECIFICATION W-F-408E, NEMA FB1 INCLUDES (2) SET SCREW
$
10.07
Qty:
Part #:STSSCN400
- SET SCREW TYPE STEEL MATERIAL IMC/RIGID/EMT CONDUIT USED ON UL 514B, CUL APPROVAL 4 STANDARD PACKAGE 4 INCH TRADE SIZE CONCRETE-TIGHT NON-INSULATED THROAT TYPE ROHS COMPLIANT APPLICABLE STANDARD FEDERAL SPECIFICATION W-F-408E, NEMA FB1 INCLUDES (2) SET SCREW
$
11.83
Qty:
Part #:PULLELERER034G
- DIE-CAST ZINC, NEOPRENE GASKET MATERIAL IMC/RIGID CONDUIT USED ON THREADED MALE/FEMALE INSTALLATION UL 514B APPROVAL 50 STANDARD PACKAGE 3/4 INCH TRADE SIZE 90 DEGREE BEND ANGLE
$
9.42
Qty:
Displaying: 1 - 9 of 9 Matching Items