Ground Fault Self Test
Eaton
View:
Active Filters :
- Brand Name: Eaton
- Special Features: Ground Fault Self Test meets or exceeds the requirements specified in ibc ®2006, cbc2007, and ubc®zone 4. audible alarm with silence button. form c relay contact. emi/rfi filtering, providing up to 50 db of noise attenuation from 10 khz to 100 mhz. surge counter with rest button No Feed-Thru Lugs
Part #:CUT3BR1224L200
- MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 27 INCH H SIZE 24 MAX. NUMBER OF CIRCUITS (12) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL C4 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
Qty:
Part #:CUT3BR1836L150
- MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 23 INCH H SIZE 36 MAX. NUMBER OF CIRCUITS (18) 1 INCH MAX. NUMBER OF SPACES UL APPROVAL 208 VAC STAR/120 VAC, 240 VAC VOLTAGE RATING 25 KILOAMPERE INTERRUPTING RATING 150 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1, INDOOR ENCLOSURE TYPE 3-PHASE 4-WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE TOP/BOTTOM FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL C2 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$
303.51
Qty:
Part #:CUT3BR3042L200
- MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 34-1/8 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (30) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL G1 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$
280.76
Qty:
Part #:CUT3BR4242B200
- MAIN BREAKER TYPE 14-5/16 INCH W X 3-7/8 INCH D X 45 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL CC MAIN BREAKER TYPE L2 ENCLOSURE SIZE DESIGNATION 1 AWG TO 250 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$
827.61
Qty:
Part #:CUT3BR4242L200
- MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 39 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL L1 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$
671.70
Qty:
$
105.53
Qty:
Part #:CUTCH250GFT
- COMMON TRIP TYPE TYPE CH LOADCENTER USED ON 14 TO 6 AWG (ALUMINUM/COPPER) WIRE SIZE 120/240 VOLT AC VOLTAGE RATING PLUG-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 50 AMP CURRENT RATING 2 POLE(S) CUTLER-HAMMER BRAND SPACING SIZE (2) 3/4 INCH
$
227.08
Qty:
Part #:CUT3BR4242B200R
- MAIN BREAKER TYPE 14-5/16 INCH W X 5-3/16 INCH D X 45 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING NEMA 3R OUTDOOR RAIN PROOF ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL CC MAIN BREAKER TYPE L2R ENCLOSURE SIZE DESIGNATION 1 AWG TO 250 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$
1,631.77
Qty:
Part #:CUTSPD100480D2A
- Eaton Surge Protection Device, SPD Series, 100 kA per phase, 480V delta (3W+G) rating, 640 L-G, 640 L-L MCOV, Internal integrated, Standard feature package, used with Direct bus mounted panel boards (PRL1a, 2a, 3a, 3e) SPD Products
$
2,785.42
Qty:
Displaying: 1 - 9 of 9 Matching Items