meets or exceeds the requirements specified in ibc ®2006, cbc2007, and ubc®zone 4. audible alarm with silence button. form c relay contact. emi/rfi filtering, providing up to 50 db of noise attenuation from 10 khz to 100 mhz. surge counter with rest button
Ground Fault Self Test


Displaying: 1 - 15 of 15 Matching Items
Part #:ON034
THREADED MALE, 3/4 INCH OFFSET TYPE DIE-CAST ZINC MATERIAL RIGID CONDUIT USED ON UL 514B APPROVAL 100 STANDARD PACKAGE 3/4 INCH TRADE SIZE NON-INSULATED THROAT TYPE
$ 3.42
Qty:
add to cart
Part #:ON112
THREADED MALE, 3/4 INCH OFFSET TYPE DIE-CAST ZINC MATERIAL RIGID CONDUIT USED ON UL 514B APPROVAL 50 STANDARD PACKAGE 1-1/2 INCH TRADE SIZE NON-INSULATED THROAT TYPE
$ 8.75
Qty:
add to cart
Part #:CUT3BR1224L200
MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 27 INCH H SIZE 24 MAX. NUMBER OF CIRCUITS (12) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL C4 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$627.00 MSRP $ 337.68
Qty:
add to cart
Part #:ON200
THREADED MALE, 3/4 INCH OFFSET TYPE DIE-CAST ZINC MATERIAL RIGID CONDUIT USED ON UL 514B APPROVAL 20 STANDARD PACKAGE 2 INCH TRADE SIZE NON-INSULATED THROAT TYPE
$ 13.43
Qty:
add to cart
Part #:CUT3BR1836L150
MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 23 INCH H SIZE 36 MAX. NUMBER OF CIRCUITS (18) 1 INCH MAX. NUMBER OF SPACES UL APPROVAL 208 VAC STAR/120 VAC, 240 VAC VOLTAGE RATING 25 KILOAMPERE INTERRUPTING RATING 150 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1, INDOOR ENCLOSURE TYPE 3-PHASE 4-WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE TOP/BOTTOM FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL C2 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 303.51
Qty:
add to cart
Part #:ON012
THREADED MALE, 3/4 INCH OFFSET TYPE DIE-CAST ZINC MATERIAL RIGID CONDUIT USED ON UL 514B APPROVAL 100 STANDARD PACKAGE 1/2 INCH TRADE SIZE NON-INSULATED THROAT TYPE
$ 2.60
Qty:
add to cart
Part #:ON100
THREADED MALE, 3/4 INCH OFFSET TYPE DIE-CAST ZINC MATERIAL RIGID CONDUIT USED ON UL 514B APPROVAL 100 STANDARD PACKAGE 1 INCH TRADE SIZE NON-INSULATED THROAT TYPE
$ 8.81
Qty:
add to cart
Part #:ON114
THREADED MALE, 3/4 INCH OFFSET TYPE DIE-CAST ZINC MATERIAL RIGID CONDUIT USED ON UL 514B APPROVAL 50 STANDARD PACKAGE 1-1/4 INCH TRADE SIZE NON-INSULATED THROAT TYPE
$ 6.72
Qty:
add to cart
Part #:CUT3BR3042L200
MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 34-1/8 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (30) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL G1 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 280.76
Qty:
add to cart
Part #:CUT3BR4242B200
MAIN BREAKER TYPE 14-5/16 INCH W X 3-7/8 INCH D X 45 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL CC MAIN BREAKER TYPE L2 ENCLOSURE SIZE DESIGNATION 1 AWG TO 250 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 827.61
Qty:
add to cart
Part #:CUT3BR4242L200
MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 39 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL L1 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 671.70
Qty:
add to cart
$ 151.47
Qty:
add to cart
Part #:CUTCH250GFT
COMMON TRIP TYPE TYPE CH LOADCENTER USED ON 14 TO 6 AWG (ALUMINUM/COPPER) WIRE SIZE 120/240 VOLT AC VOLTAGE RATING PLUG-ON MOUNTING 10 KILOAMP INTERRUPTING RATING 50 AMP CURRENT RATING 2 POLE(S) CUTLER-HAMMER BRAND SPACING SIZE (2) 3/4 INCH
$ 227.08
Qty:
add to cart
Part #:CUT3BR4242B200R
MAIN BREAKER TYPE 14-5/16 INCH W X 5-3/16 INCH D X 45 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING NEMA 3R OUTDOOR RAIN PROOF ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL CC MAIN BREAKER TYPE L2R ENCLOSURE SIZE DESIGNATION 1 AWG TO 250 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 1,631.77
Qty:
add to cart
Part #:CUTSPD100480D2A
Eaton Surge Protection Device, SPD Series, 100 kA per phase, 480V delta (3W+G) rating, 640 L-G, 640 L-L MCOV, Internal integrated, Standard feature package, used with Direct bus mounted panel boards (PRL1a, 2a, 3a, 3e) SPD Products
$ 2,785.42
Qty:
add to cart
 
Displaying: 1 - 15 of 15 Matching Items