Ul (Canada and Us)
EATON CORPORATION
View:
Active Filters :
- Mfr / Trade Name: EATON CORPORATION
- Standard: Ul (Canada and Us) Ul 489,Federal Specifications Classification W-C375 Ul Listed File E8741
$
7.31
Qty:
$
6.96
Qty:
$
18.15
Qty:
$
18.15
Qty:
$
18.15
Qty:
$
59.51
Qty:
Part #:CUTBD2020
- THERMAL MAGNETIC DUPLEX INDEPENDENT TRIP TYPE LOAD CENTER USED ON 14 TO 4 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489 APPROVAL 120 VAC VOLTAGE RATING PLUG ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 20 AMPERE (OUTSIDE POLE INSIDE POLE) CURRENT RATING 2 POLE(S) BD MODEL
Qty:
$
35.74
Qty:
$
30.39
Qty:
Part #:CUTTP431MSB
- WELDED STEEL MATERIAL 4 INCH 4 INCH 2-1/8 INCH UL 514A/514B/514C APPROVAL MSB BRACKET MOUNTING 25 STANDARD PACKAGE 30.3 CU INCH CAPACITY (1) 1/2 INCH BOTTOM, (4) CABLE SIDE, (4) 1/2 INCH SIDE, (2) (1/2 INCH-3/4 INCH) ECCENTRIC SIDE KNOCKOUT SIZE 11 KNOCKOUT(S) (1) BOTTOM, (6) SIDE, (4) CABLE SIDE KNOCKOUT LOCATION ARMORED/METAL CLAD CABLE CLAMP TYPE APPLICABLE STANDARD FEDERAL SPECIFICATION W-J-800E, NEMA OS-1
$
20.97
Qty:
Part #:CUTBR380
- COMMON TRIP THERMAL MAGNETIC TYPE LOAD CENTER USED ON 4 TO 1/0 AWG (ALUMINUM/COPPER) WIRE SIZE 240 VAC VOLTAGE RATING PLUG ON MOUNTING 10000 AMPERE INTERRUPTING RATING 80 AMPERE CURRENT RATING 3 POLE(S) LUG TERMINAL TYPE BR MODEL
Qty:
Part #:CUTCHSUR42L225L2
- MAIN LUG TYPE 14.31 INCH W X 3.88 INCH D X 39 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS UL APPROVAL 120/240 VAC VOLTAGE RATING 225 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1, INDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION TWIN NEUTRAL TYPE BOTTOM/TOP FEED LOCATION SILVER FLASH PLATED COPPER BUS MATERIAL L ENCLOSURE SIZE DESIGNATION 2 AWG TO 300 KCMIL MAIN WIRE SIZE CUTLER-HAMMER[R] BRAND INCLUDES FACTORY INSTALLED SURGE SUPPRESSION, GROUND BAR CH MODEL
$
1,216.07
Qty:
$
7.31
Qty:
Part #:CUTBR150
- THERMAL MAGNETIC TYPE LOAD CENTER USED ON 14 TO 4 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489 APPROVAL 120/240 VAC VOLTAGE RATING PLUG ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 50 AMPERE CURRENT RATING 1 POLE(S) BR MODEL
$
6.96
Qty:
Part #:CUTBR2125
- THERMAL MAGNETIC MAIN TYPE LOAD CENTER USED ON 4 TO 2/0 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING 2 POLE(S) BR MODEL
Qty:
Part #:CUTBJ2150
- THERMAL MAGNETIC COMMON TRIP TYPE LOAD CENTER USED ON 2 AWG TO 300 KCMIL (ALUMINUM/COPPER) WIRE SIZE UL 489 APPROVAL 120/240 VAC VOLTAGE RATING PLUG ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 150 AMPERE CURRENT RATING 2 POLE(S) BJ MODEL
$
120.87
Qty:
Part #:CUTBJ2200
- THERMAL MAGNETIC COMMON TRIP TYPE LOAD CENTER USED ON 2 AWG TO 300 KCMIL (ALUMINUM/COPPER) WIRE SIZE UL 489 APPROVAL 120/240 VAC VOLTAGE RATING PLUG ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING 2 POLE(S) BJ MODEL
$
258.05
Qty:
$
76.58
Qty:
Displaying: 1 - 24 of 30 Matching Items