Ul 489
Ccsaus Certified, Hvacr


Displaying: 1 - 24 of 43 Matching Items
43 Items
View:
Active Filters :
Part #:CUTBW2100

THERMAL MAGNETIC TYPE ECB UNIT ENCLOSURE USED ON 2 AWG TO 300 KCMIL (ALUMINUM/COPPER) WIRE SIZE UL 489, CSA APPROVAL 120/240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 100 AMPERE CURRENT RATING 2 POLE(S) LINE TERMINAL TERMINAL TYPE BW MODEL
$ 119.55
Part #:CUTBW2150

THERMAL MAGNETIC MAIN TYPE LOAD CENTER USED ON 2 AWG TO 300 KCMIL (ALUMINUM/COPPER) WIRE SIZE UL 489 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 150 AMPERE CURRENT RATING 2 POLE(S)
$ 105.76
Part #:CUTBW2200

THERMAL MAGNETIC MAIN TYPE LOAD CENTER USED ON 2 AWG TO 300 KCMIL (ALUMINUM/COPPER) WIRE SIZE UL 489 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING 2 POLE(S)
$ 119.55
Part #:INTMT101

24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$ 113.80
Part #:INTMT104

24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 208 TO 277 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 5 HP AT 240 VOLT AC 1-PHASE (28 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$ 136.46
Part #:INTMT103

24 HOUR TYPE STEEL MATERIAL 5-1/8 INCH WIDTH X 3-7/16 INCH DEPTH X 7-7/8 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, SIGN, POOL HEATER, BLOWER, ELECTRIC FENCE, PUMP, FAN, CONVEYER, OTHER ELECTRICAL LOAD APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE), 1000 VOLT AMP AT 120 TO 277 VOLT AC (PILOT DUTY) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA), 5 HP AT 240 VOLT AC (28 FLA) 1-PHASE POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND MAXIMUM POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT DIMENSION (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BOTTOM) INCLUDES ON/OFF TRIPPER T100 MODEL
$ 133.50
Part #:INTMT101R

24 HOUR TYPE STEEL MATERIAL 5-1/2 INCH WIDTH X 3-5/8 INCH DEPTH X 9-3/8 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 3R ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$ 165.84
Part #:CUTCSR2200N

MAIN TYPE CH MAIN BREAKER LOADCENTER USED ON 120/240 VAC VOLTAGE RATING 25 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING 2 POLE(S) CUTLER-HAMMER[R] BRAND CSR MODEL
$ 285.32
Part #:CUTNL30

GROUND/NEUTRAL LUG TYPE TYPE CH LOADCENTER USED ON 1 QUANTITY
$29.00 MSRP $ 24.03
Part #:CUTNL300

GROUND/NEUTRAL LUG TYPE TYPE CH LOADCENTER USED ON 1 QUANTITY
$ 31.81
Part #:CUTCH2150

THERMAL MAGNETIC, COMMON TRIP TYPE CH SERIES LOADCENTER USED ON 3/0 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489, CSA APPROVAL 120/240 VAC VOLTAGE RATING PLUG-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 150 AMPERE CURRENT RATING 2 POLE(S) CH MODEL
$ 318.02
Part #:CUTCCV2100

THERMAL MAGNETIC TYPE 1MP/1MM/3MM SERIES MODULAR METER STACK USED ON 2 AWG TO 300 KCMIL (ALUMINUM/COPPER) WIRE SIZE UL 489 APPROVAL 120/240 VAC VOLTAGE RATING BOLT-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 100 AMPERE CURRENT RATING 2 POLE(S)
$ 404.37
Part #:CUTCHHT

$ 3.45 E
Part #:CUTNL20

GROUND/NEUTRAL LUG TYPE TYPE CH LOADCENTER USED ON 1 QUANTITY
$ 15.43
Part #:CUTLCCS

COVER SCREW TYPE TYPE CH LOADCENTER AND CIRCUIT BREAKER USED ON STANDARD PACKAGE 25
$3.05 MSRP $ 2.50
Part #:CUTCH290

COMMON TRIP THERMAL MAGNETIC TYPE LOAD CENTER USED ON 10 TO 1/0 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489 CSA APPROVAL 120/240 VAC VOLTAGE RATING PLUG ON MOUNTING 10000 AMPERE INTERRUPTING RATING 90 AMPERE CURRENT RATING 2 POLE(S) CH MODEL
$ 118.34
Part #:CUTCH315

COMMON TRIP THERMAL MAGNETIC TYPE LOAD CENTER USED ON UL 489 CSA APPROVAL 240 VAC VOLTAGE RATING PLUG ON MOUNTING 10000 AMPERE INTERRUPTING RATING 15 AMPERE CURRENT RATING 3 POLE(S) CH MODEL
$ 156.81
 
Displaying: 1 - 24 of 43 Matching Items