Part #:CUTMSH5-0A

MANUAL STARTER USED ON UL CSA APPROVAL PLUG IN MOUNTING 4 TO 4.39 AMPERE MOTOR FLA STANDARD TRIP TYPE MSH MODEL
$35.75 MSRP $ 30.50
Part #:CUTMSH8-0A

MANUAL STARTER USED ON UL CSA APPROVAL PLUG IN MOUNTING 6.4 TO 7.03 AMPERE MOTOR FLA STANDARD TRIP TYPE MSH MODEL
$35.75 MSRP $ 30.50
Part #:CUTFH03

MANUAL STARTER USED ON UL CSA APPROVAL 2 STANDARD PACKAGE M-0 (ENCLOSED) M-1 (ENCLOSED) NEMA SIZE 0.28 TO 0.29 AMPERE MOTOR FLA STANDARD TRIP TYPE FH MODEL
$ 79.89
Part #:MILBU5168-XTL-200-KK

RINGLESS TYPE 14-1/8 INCH W X 4-1/2 INCH D X 32 INCH H SIZE 6 AWG TO 350 KCMIL (LINE) WIRE SIZE GALVANIZED STEEL ENCLOSURE MATERIAL UL APPROVAL 240 VAC VOLTAGE RATING SURFACE MOUNTING NEMA 3R ENCLOSURE 200 AMPERE CURRENT RATING 1-PHASE 3-WIRE CIRCUIT CONFIGURATION OVERHEAD/UNDERGROUND SERVICE TYPE 8 CIRCUIT(S) CLOSING PLATE HUB TYPE (1) (1/4 INCH - 1/2 INCH), (4) (1/2 INCH - 3/4 INCH), (2) (1/2 INCH - 3/4 INCH - 1 INCH), (3) (3/4 INCH - 1 INCH - 1-1/4 INCH - 1-1/2 INCH - 2 INCH), (1) (1 INCH - 1-1/4 INCH - 1-1/2 INCH - 2 INCH - 2-1/2 INCH), (1) (1-1/4 INCH - 1-1/2 INCH - 2 INCH - 2-1/2 INCH - 3 INCH) CONCENTRIC KNOCKOUT KNOCKOUT(S) 4 JAW(S) HORN BYPASS SWITCH 22 KILOAMPERE INTERRUPTING RATING CIRCUIT BREAKER MAIN DISCONNECT TYPE U5168 MODEL
$ 359.09
Part #:MILU7021-RL-TG-KK-RGE

200 AMP O/H AND UNDERGROUND RESIDENTIAL WITH TEST TABS:
$ 91.14
Part #:CUTAN16BN0AC

FULL VOLTAGE, NON-REVERSING TYPE NEMA 0 SIZE 18 AMP CURRENT RATING OPEN ENCLOSURE TYPE NEMA CONSTRUCTION STANDARD 110 VOLT AC AT 50 HERTZ, 120 VOLT AC AT 60 HERTZ COIL VOLTAGE 1NO AUXILIARY CONTACT 1 HP AT 115 VOLT 1-PHASE, 2 HP AT 230 VOLT 1-PHASE, 3 HP AT 208/240 VOLT 3-PHASE, 5 HP AT 380/480/600 VOLT 3-PHASE POWER RATING/VOLTAGE BI-METALLIC AMBIENT COMPENSATED OVERLOAD RELAY OVERLOADS 1 OR 3 PHASE CUTLER-HAMMER BRAND NUMBER OF POLES 3 MOUNTING TYPE HORIZONTAL APPROVAL UL, CSA FREEDOM, AN16 MODEL
$ 832.77
Part #:CUTAN16DN0AB

FULL VOLTAGE NON REVERSING TYPE NEMA 1 SIZE 27 AMPERE CURRENT RATING OPEN ENCLOSURE TYPE NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ 120 VAC AT 60 HZ COIL VOLTAGE 1NO RIGHT MOUNT AUXILIARY CONTACT 2 HP AT 115 V 1 PHASE 3 HP AT 230 V 1 PHASE 7-1/2 HP AT 208/240 V 3 PHASE 10 HP AT 380 V 50 HZ/480/600 V 3 PHASE POWER RATING/VOLTAGE BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS 1/3 PHASE APPROVAL UL CSA APPLICABLE STANDARD IEC 158 NEMA VDE BS NUMBER OF POLE 3 AN16 MODEL
$ 885.34
Part #:CUTC306GN3B

$ 292.01 E
Part #:MILU7421-RL

RINGLESS TYPE 10 INCH W X 4-7/8 INCH D X 18-1/2 INCH H SIZE 6 AWG TO 350 KCMIL (LINE/LOAD, ALUMINUM/COPPER) WIRE SIZE UL 414 APPROVAL 600 VAC VOLTAGE RATING NEMA 3R ENCLOSURE 200 AMPERE CURRENT RATING 3 PHASE 4 WIRE CIRCUIT CONFIGURATION OVERHEAD SERVICE TYPE TRIPLEX NEUTRAL NEUTRAL TYPE SMALL OPENING HUB TYPE (1) (1/4-INCH-1/2 INCH) CONCENTRIC KNOCKOUT, (2) 3/4 INCH CONCENTRIC KNOCKOUT, (1) 2 1/2 INCH CONCENTRIC KNOCKOUT, (2) 3 INCH CONCENTRIC KNOCKOUT KNOCKOUT(S) 7 JAW(S) LEVER BYPASS SWITCH APPLICABLE STANDARD ANSI C12.7
$ 490.66
Part #:MILU7487-RL-TG-KK

RINGLESS TYPE 8 INCH W X 3-5/16 INCH D X 11-1/2 INCH H SIZE 6 TO 2/0 AWG (LINE/LOAD, ALUMINUM/COPPER) WIRE SIZE UL 414 APPROVAL 600 VAC VOLTAGE RATING NEMA 3R ENCLOSURE 125 AMPERE CURRENT RATING OVERHEAD/UNDERGROUND SERVICE TYPE TRIPLEX NEUTRAL NEUTRAL TYPE SMALL OPENING HUB TYPE (1) 1/4 INCH CONCENTRIC KNOCKOUT, (2) 1 1/4 INCH CONCENTRIC KNOCKOUT, (2) 1 1/2 INCH CONCENTRIC KNOCKOUT, (1) 2 INCH CONCENTRIC KNOCKOUT KNOCKOUT(S) 4 JAW(S) HORN BYPASS SWITCH APPLICABLE STANDARD ANSI C12.7
$ 84.00
Part #:MILU7040-RL-TG-KK-RGE

RINGLESS TYPE 11 INCH W X 4 1/8 INCH D X 15 1/2 INCH H SIZE 6 AWG TO 350 KCMIL (LINE), 6 AWG TO 350 KCMIL (LOAD) WIRE SIZE UL APPROVAL 200 AMPERE CURRENT RATING OVERHEAD/UNDERGROUND SERVICE TYPE (1) 1/4 INCH, (1) (1/4 INCH-1/2 INCH) CONCENTRIC KNOCKOUT, (4) 2 1/2 INCH KNOCKOUT(S) 4 JAW(S) HORN BYPASS SWITCH MILBANK[R] BRAND
$ 70.50
Part #:MILBU5168-XTL-100-KK

METER MAIN, RINGLESS TYPE 14 1/8 INCH W X 4 1/2 INCH D X 32 INCH H SIZE 6 AWG TO 350 KCMIL (LINE) WIRE SIZE POWDER COATED G90 GALVANIZED STEEL ENCLOSURE MATERIAL UL APPROVAL 0 TO 240 VAC AT 60 HZ VOLTAGE RATING SURFACE MOUNTING NEMA 3R ENCLOSURE 100 AMPERE CURRENT RATING 1 PHASE 3 WIRE CIRCUIT CONFIGURATION OVERHEAD/UNDERGROUND SERVICE TYPE (2) SMALL CLOSING PLATE HUB TYPE (1) 2 INCH, (2) 2 INCH, (3) 3 INCH, (4) 2 1/2 INCH, (5) (1/2 INCH, 3/4 INCH, 1 INCH), (6) (1/2 INCH, 3/4 INCH) KNOCKOUT(S) 4 JAW(S) HORN BYPASS SWITCH 100 AMPERE INTERRUPTING RATING CIRCUIT BREAKER MAIN DISCONNECT TYPE 8 BRANCH CIRCUIT PROVISION APPLICATION METER MOUNTING BASE U5168 MODEL
$ 359.07
Part #:CUTMSH12-9A

MANUAL STARTER USED ON UL CSA APPROVAL PLUG IN MOUNTING 10.31 TO 11.35 AMPERE MOTOR FLA STANDARD TRIP TYPE MSH MODEL
$35.75 MSRP $ 30.50
Part #:CUTBAB2080

THERMAL MAGNETIC TYPE 8 TO 1/0 AWG (COPPER/ALUMINUM) WIRE SIZE UL 489, CSA APPROVAL 120/240 VOLT AC VOLTAGE RATING BOLT-ON MOUNTING 10 KILOAMP AT 120/240 VOLT AC, 5 KILOAMP AT 24 TO 48/62.5/80 VOLT DC INTERRUPTING RATING 80 AMP AT 40 DEG C CURRENT RATING 2 POLE(S) EXTENDED TANG LINE, BOX LUG LOAD TERMINAL TYPE CUTLER-HAMMER BRAND APPLICATION HEATING, AIR CONDITIONING, REFRIGERATION, 120 VOLT FLUORESCENT LIGHT SWITCHING DUTY APPLICABLE STANDARD FEDERAL SPECIFICATION W-C-375B BAB MODEL
$ 105.93
Part #:CUTBAB2100

THERMAL MAGNETIC TYPE 8 TO 1/0 AWG (ALUMINUM/COPPER LOAD) WIRE SIZE UL 489 CSA APPROVAL 120/240 VAC VOLTAGE RATING BOLT ON MOUNTING 10000 AMPERE AT 120/240 VAC 5000 AMPERE AT 24 TO 48/62.5/80 VDC INTERRUPTING RATING 100 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) EXTENDED TANG LINE TERMINAL BOX LUG LOAD TERMINAL TERMINAL TYPE QUICKLAG[R] BRAND BAB MODEL
$298.00 MSRP $ 127.11
 