Ul Listed,Federal Specifications Classification W-C375b
Ul 217, Nfpa 72, (Chapter 11) the State of California Fire Marshall, Nfpa 101 (One and Two Family Dwellings), Federal Housing Authority (Fha), Housing and Urban Development (Hud)


Displaying: 1 - 9 of 9 Matching Items
9 Items
View:
Part #:CUTGHB3020

MOLDED CASE, THERMAL MAGNETIC TYPE 3.8 INCH WIDTH X 6.6 INCH DEPTH X 4 INCH HEIGHT SIZE 480 VOLT MAX. AC VOLTAGE RATING 250 VOLT MAX. DC VOLTAGE RATING UL 489, CSA C22.2 APPROVAL 277/480 VOLT AC AT 50/60 HERTZ, 125/250 VOLT DC VOLTAGE RATING 14 KILOAMP AT 480 VOLT AC STAR/277 VOLT AC/125/250 VOLT DC INTERRUPTING RATING 20 AMP AT 40 DEG C CURRENT RATING 3 POLE(S) SCREW TYPE CLAMP LINE AND LOAD TERMINAL TYPE G FRAME TYPE CUTLER-HAMMER BRAND MOUNTING TYPE BOLT-ON APPLICATION PANELBOARD, SWITCHBOARD, MOTOR CONTROL CENTER APPLICABLE STANDARD NEMA AB1, AS 2184, BS 4752, IEC 157-1, SABS 156, SEV 157-1, VDE 0660 C, GHB MODEL
$ 269.27
Part #:CUTGHB3040

MOLDED CASE THERMAL MAGNETIC TYPE 3 INCH W X 2.63 INCH D X 4 INCH H SIZE 480 MAX. AC VOLTAGE RATING 250 MAX. DC VOLTAGE RATING UL 489 CSA APPROVAL 277/480 VAC AT 50/60 HZ 125/250 VDC VOLTAGE RATING 14 KILOAMPERE AT 480 VAC STAR/277 VAC/125/250 VDC INTERRUPTING RATING 40 AMPERE AT 40 DEG C CURRENT RATING 3 POLE(S) ALUMINUM PRESSURE LINE AND LOAD TERMINAL TERMINAL TYPE GHB FRAME TYPE GHB MODEL
$ 292.68
Part #:KIDI4618A

The Kidde i4618 is an AC/DC powered, ionization smoke alarm that operates on a 120V power source with 9V battery backup. This alarm uses ionization sensing technology. Ionization sensing alarms may detect invisible fire particles (associated with flaming fires) sooner than photoelectric alarms. Photoelectric sensing alarms may detect visible particles (associated with smoldering fires) sooner than ionization alarms. The front-loading battery door allows user to change the battery without removing the alarm from the mounting bracket making battery replacement easy and convenient. This smoke alarm is available in a 6-piece cut case with tray for easy display as well as a 6-piece bulk pack for contractors and property owners. This unit is a UL Listed product with a 5-year limited warranty. Kidde strongly recommends that both ionization and photoelectric smoke alarms be installed to help insure maximum detection of the various types of fire that can occur within the home. Easy Installation &bull Front battery pull tab allows battery activation without removing alarm from mounting bracket. &bull Large mounting base makes mounting easier, protects surface paint from dirt and covers imperfections. &bull Pre-stripped wiring harness with easy off cap does not require stripper tool. Tinned strands increase conductivity and wire nut grip. Fewer Callbacks &bull Large centrally located Test/Hush&reg alarm control button. &bull Dust cover protects sensor from contaminates during construction reducing nuisance alarms. User-Friendly Features &bull Easy access front loading battery door. &bull Battery backup provides protection in case of power failure. &bull Interconnectable with up to 24 devices (of which 18 can be initiating) including smoke, CO and heat alarms. See user&rsquos guide for complete instructions. Technical Specifications Model i4618 UPC 0-47871-07581-2 Power Source 120VAC (80mA Max) Sensor Ionization Audio Alarm 85dB at 10ft Temperature Range 40&degF (4.4&degC) to 100&degF (37.8&degC) Humidity Range Up to 85% relative humidity (RH) Size 5.6 in diameter x 1.8 in depth Weight .5lbs Interconnects Up to 24 Kidde devices LED Green, receiving ac power,Red, 4 modes of operation Warranty 5 year limited
$ 12.77
Part #:I12040

SMOKE ALARM WITH STROBE LIGHT TYPE AC/DC IONIZATION OPERATION TYPE UL APPROVAL 85 DB AT 10 FT HORN TYPE 120 VAC 60 HZ WITH 9 V BATTERY BACKUP VOLTAGE RATING/SOURCE LED INDICATING CONDITION LED/STROBE TYPE 24 INTERCONNECTION(S) SIZE 6.5 INCH W X 13.25 INCH D X 6 INCH H
$ 23.04
Part #:CUTGHB1030

MOLDED CASE THERMAL MAGNETIC TYPE 277 MAX. AC VOLTAGE RATING 125 MAX. DC VOLTAGE RATING 480 VAC STAR/277 VAC AT 50/60 HZ 125 VDC VOLTAGE RATING 65 KILOAMPERE AT 120 VAC 14 KILOAMPERE AT 277 VAC/125 VDC INTERRUPTING RATING 30 AMPERE AT 40 DEG C CURRENT RATING 1 POLE(S) ALUMINUM PRESSURE LINE TERMINAL PRESSURE LOAD TERMINAL TERMINAL TYPE G FRAME TYPE APPLICABLE STANDARD AS 2184 BS 4752 IEC 157-1 NEMA AB-1 NF C 63-120 SABS 156 SEV 157-1 VDE 0660 MAXIMUM AC VOLTAGE RATING - UOM V MAXIMUM DC VOLTAGE RATING - UOM V GHB MODEL
$ 63.69
Part #:CUTGHB1015

Eaton Series C complete molded case circuit breaker, G-frame, GHB, Complete breaker, Fixed thermal, Fixed magnetic trip type, Single-pole, 15 A, 277 Vac, 125 Vdc, 14 kAIC at 277 Vac, 50/60 Hz
$ 69.23
Part #:CUTGHB1020

Eaton Series C complete molded case circuit breaker, G-frame, GHB, Complete breaker, Fixed thermal, Fixed magnetic trip type, Single-pole, 20 A, 277 Vac, 125 Vdc, 14 kAIC at 277 Vac, 50/60 Hz
$ 69.23
Part #:CUTGHB2030

MOLDED CASE THERMAL MAGNETIC TYPE 480 MAX. AC VOLTAGE RATING 250 MAX. DC VOLTAGE RATING UL 489 CSA APPROVAL 277/480 VAC AT 50/60 HZ 125/250 VDC VOLTAGE RATING 14 KILOAMPERE AT 480 VAC STAR/277 VAC/125/250 VDC INTERRUPTING RATING 30 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) ALUMINUM PRESSURE LINE AND LOAD TERMINAL TERMINAL TYPE GHB FRAME TYPE GHB MODEL
$412.00 MSRP $ 152.57
 