Ul Listed,Federal Specifications Classification W-C375b
Ul 50,Ul 67


Displaying: 1 - 24 of 39 Matching Items
39 Items
View:
Part #:CUTGHB3020

MOLDED CASE, THERMAL MAGNETIC TYPE 3.8 INCH WIDTH X 6.6 INCH DEPTH X 4 INCH HEIGHT SIZE 480 VOLT MAX. AC VOLTAGE RATING 250 VOLT MAX. DC VOLTAGE RATING UL 489, CSA C22.2 APPROVAL 277/480 VOLT AC AT 50/60 HERTZ, 125/250 VOLT DC VOLTAGE RATING 14 KILOAMP AT 480 VOLT AC STAR/277 VOLT AC/125/250 VOLT DC INTERRUPTING RATING 20 AMP AT 40 DEG C CURRENT RATING 3 POLE(S) SCREW TYPE CLAMP LINE AND LOAD TERMINAL TYPE G FRAME TYPE CUTLER-HAMMER BRAND MOUNTING TYPE BOLT-ON APPLICATION PANELBOARD, SWITCHBOARD, MOTOR CONTROL CENTER APPLICABLE STANDARD NEMA AB1, AS 2184, BS 4752, IEC 157-1, SABS 156, SEV 157-1, VDE 0660 C, GHB MODEL
$ 269.27
Part #:CUTGHB3040

MOLDED CASE THERMAL MAGNETIC TYPE 3 INCH W X 2.63 INCH D X 4 INCH H SIZE 480 MAX. AC VOLTAGE RATING 250 MAX. DC VOLTAGE RATING UL 489 CSA APPROVAL 277/480 VAC AT 50/60 HZ 125/250 VDC VOLTAGE RATING 14 KILOAMPERE AT 480 VAC STAR/277 VAC/125/250 VDC INTERRUPTING RATING 40 AMPERE AT 40 DEG C CURRENT RATING 3 POLE(S) ALUMINUM PRESSURE LINE AND LOAD TERMINAL TERMINAL TYPE GHB FRAME TYPE GHB MODEL
$ 292.68
Part #:CUTCH42B3200L

$ 1,221.81 E
Part #:CUTCH4L125SP

MAIN LUG TYPE 11 INCH W X 3-11/16 INCH D X 13 INCH H SIZE 8 MAX. NUMBER OF CIRCUITS (4) 3/4 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 1699 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING SURFACE WITHOUT DOOR COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION COPPER BUS MATERIAL 7 ENCLOSURE SIZE DESIGNATION 14 TO 1/0 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE CH MODEL
$ 49.29
Part #:CUTCH2L125SP

MAIN LUG TYPE 6-7/8 INCH W X 3-25/64 INCH D X 11-3/8 INCH H SIZE 4 MAX. NUMBER OF CIRCUITS (2) 3/4 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 1699 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING SURFACE WITHOUT DOOR COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION COPPER BUS MATERIAL 6 ENCLOSURE SIZE DESIGNATION 14 TO 1/0 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE CH MODEL
$ 55.31
Part #:CUTCH8L125SP

MAIN LUG TYPE 11 INCH W X 3-11/16 INCH D X 13 INCH H SIZE 16 MAX. NUMBER OF CIRCUITS (8) 3/4 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 1699 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING SURFACE WITHOUT DOOR COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION COPPER BUS MATERIAL 7 ENCLOSURE SIZE DESIGNATION 6 TO 1/0 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE CH MODEL
$ 69.59
Part #:CUTCH8L125RP

MAIN LUG TYPE 11 INCH W X 3-11/16 INCH D X 13 INCH H SIZE 16 MAX. NUMBER OF CIRCUITS (8) 3/4 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 1699 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING NEMA 3R OUTDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION COPPER BUS MATERIAL 7R ENCLOSURE SIZE DESIGNATION 6 TO 1/0 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE CH MODEL
$ 124.10
Part #:CUTBR612L125RP

MAIN LUG TYPE 11 INCH W X 3-9/16 INCH D X 13 INCH H SIZE 12 MAX. NUMBER OF CIRCUITS (6) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING NEMA 3R OUTDOOR RAIN PROOF ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL 7R ENCLOSURE SIZE DESIGNATION 14 TO 1 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 93.52
Part #:CUTBR612L125SP

MAIN LUG TYPE 11 INCH W X 3-9/16 INCH D X 13 INCH H SIZE 12 MAX. NUMBER OF CIRCUITS (6) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING SURFACE WITHOUT DOOR COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL 7 ENCLOSURE SIZE DESIGNATION 14 TO 1 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 58.49
Part #:CUT3BR4242B200R

MAIN BREAKER TYPE 14-5/16 INCH W X 5-3/16 INCH D X 45 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING NEMA 3R OUTDOOR RAIN PROOF ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL CC MAIN BREAKER TYPE L2R ENCLOSURE SIZE DESIGNATION 1 AWG TO 250 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 1,631.77
Part #:CUTBRP10B100RF

MAIN BREAKER TYPE 14-5/16 INCH W X 5-3/16 INCH D X 18-3/4 INCH H SIZE 20 MAX. NUMBER OF CIRCUITS (10) 1 INCH MAX. NUMBER OF SPACES UL APPROVAL 120/240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 100 AMPERE CURRENT RATING NEMA 3R, OUTDOOR, RAINPROOF ENCLOSURE TYPE 1-PHASE 3-WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE SPLIT NEUTRAL TYPE TOP/BOTTOM FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL BR MAIN BREAKER TYPE B2R ENCLOSURE SIZE DESIGNATION 4 TO 1/0 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC INCLUDES FEED THROUGH LUG FOR PHASE/NEUTRAL CONDUCTOR BR MODEL
$ 199.82
Part #:CUTGHB1030

MOLDED CASE THERMAL MAGNETIC TYPE 277 MAX. AC VOLTAGE RATING 125 MAX. DC VOLTAGE RATING 480 VAC STAR/277 VAC AT 50/60 HZ 125 VDC VOLTAGE RATING 65 KILOAMPERE AT 120 VAC 14 KILOAMPERE AT 277 VAC/125 VDC INTERRUPTING RATING 30 AMPERE AT 40 DEG C CURRENT RATING 1 POLE(S) ALUMINUM PRESSURE LINE TERMINAL PRESSURE LOAD TERMINAL TERMINAL TYPE G FRAME TYPE APPLICABLE STANDARD AS 2184 BS 4752 IEC 157-1 NEMA AB-1 NF C 63-120 SABS 156 SEV 157-1 VDE 0660 MAXIMUM AC VOLTAGE RATING - UOM V MAXIMUM DC VOLTAGE RATING - UOM V GHB MODEL
$ 63.69
Part #:CUTGHB1015

Eaton Series C complete molded case circuit breaker, G-frame, GHB, Complete breaker, Fixed thermal, Fixed magnetic trip type, Single-pole, 15 A, 277 Vac, 125 Vdc, 14 kAIC at 277 Vac, 50/60 Hz
$ 69.23
Part #:CUTGHB1020

Eaton Series C complete molded case circuit breaker, G-frame, GHB, Complete breaker, Fixed thermal, Fixed magnetic trip type, Single-pole, 20 A, 277 Vac, 125 Vdc, 14 kAIC at 277 Vac, 50/60 Hz
$ 69.23
Part #:CUTGHB2030

MOLDED CASE THERMAL MAGNETIC TYPE 480 MAX. AC VOLTAGE RATING 250 MAX. DC VOLTAGE RATING UL 489 CSA APPROVAL 277/480 VAC AT 50/60 HZ 125/250 VDC VOLTAGE RATING 14 KILOAMPERE AT 480 VAC STAR/277 VAC/125/250 VDC INTERRUPTING RATING 30 AMPERE AT 40 DEG C CURRENT RATING 2 POLE(S) ALUMINUM PRESSURE LINE AND LOAD TERMINAL TERMINAL TYPE GHB FRAME TYPE GHB MODEL
$412.00 MSRP $ 152.57
 
Displaying: 1 - 24 of 39 Matching Items