40 Amp
30a


Displaying: 1 - 22 of 22 Matching Items
22 Items
View:
Active Filters :
Part #:INTMT101

24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$ 113.80
Part #:INTMT104

24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 208 TO 277 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 5 HP AT 240 VOLT AC 1-PHASE (28 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$ 136.46
Part #:INTMT103

24 HOUR TYPE STEEL MATERIAL 5-1/8 INCH WIDTH X 3-7/16 INCH DEPTH X 7-7/8 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, SIGN, POOL HEATER, BLOWER, ELECTRIC FENCE, PUMP, FAN, CONVEYER, OTHER ELECTRICAL LOAD APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE), 1000 VOLT AMP AT 120 TO 277 VOLT AC (PILOT DUTY) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA), 5 HP AT 240 VOLT AC (28 FLA) 1-PHASE POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND MAXIMUM POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT DIMENSION (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BOTTOM) INCLUDES ON/OFF TRIPPER T100 MODEL
$ 133.50
Part #:INTMT101R

24 HOUR TYPE STEEL MATERIAL 5-1/2 INCH WIDTH X 3-5/8 INCH DEPTH X 9-3/8 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 3R ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$ 165.84
Part #:CUTDG221UGB

GENERAL DUTY SAFETY TYPE 2 WIRE(S) UL APPROVAL NEMA 1 ENCLOSURE 30 AMPERE CURRENT RATING 3 HP AT 240 VAC 1 PHASE POWER RATING 2 POLE(S) NO NEUTRAL TYPE 240 V AC VOLTAGE RATING NON FUSIBLE FUSE PROVISION APPLICABLE STANDARD NEMA KS-1 DG MODEL
$ 67.30
Part #:CUTDH361FGK

$ 201.58 E
Part #:CUTDH361FRK

$ 356.08 E
Part #:CUTDH361UGK

$ 168.50 E
Part #:CUTDH361URK

$ 184.90 E
Part #:CUTDH361NGK

HEAVY DUTY SAFETY TYPE 8-1/8 INCH W X 10 INCH D X 15-7/8 INCH H SIZE 4 WIRE(S) UL APPROVAL NEMA 1 ENCLOSURE 30 AMPERE CURRENT RATING 7-1/2 HP AT 480 VAC 1 PHASE 10 HP AT 600 VAC 1 PHASE 15 HP AT 480 VAC 3 PHASE 20 HP AT 600 VAC 3 PHASE (TIME DELAY FUSE) POWER RATING 3 POLE(S) CARTRIDGE CLASS H TIME DELAY FUSE TYPE SOLID NEUTRAL TYPE 480 V STAR/277 V 600 V STAR/347 V AC VOLTAGE RATING 250 V DC VOLTAGE RATING FUSIBLE FUSE PROVISION APPLICABLE STANDARD NEMA KS-1 DH MODEL
$ 231.25
Part #:CUTCH230GFT

COMMON TRIP THERMAL MAGNETIC TYPE LOADCENTER USED ON 14 TO 6 AWG (ALUMINUM/COPPER) WIRE SIZE UL 489 CSA APPROVAL 120/240 VAC VOLTAGE RATING PLUG ON MOUNTING 10000 AMPERE INTERRUPTING RATING 30 AMPERE CURRENT RATING 2 POLE(S) 5 MILLIAMPERE TRIP SENSITIVITY CH MODEL
$539.00 MSRP $ 227.08
Part #:CUTGFTCB230

COMMON TRIP TYPE 2 INCH W X 2.75 INCH D X 4.5 INCH H SIZE TYPE BR LOADCENTER USED ON 14 TO 4 AWG (COPPER/ALUMINUM) WIRE SIZE 120/240 VAC VOLTAGE RATING PLUG-ON MOUNTING 10 KILOAMPERE INTERRUPTING RATING 30 AMPERE CURRENT RATING 2 POLE(S) 5 MILLIAMPERE TRIP SENSITIVITY GFTCB MODEL
$ 95.91
 
Displaying: 1 - 22 of 22 Matching Items