200a
40 Amp


Displaying: 1 - 17 of 17 Matching Items
17 Items
View:
Active Filters :
Part #:INTMT101

24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$ 113.80
Part #:INTMT104

24 HOUR TYPE STEEL MATERIAL 5 INCH WIDTH X 3 INCH DEPTH X 7-3/4 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 208 TO 277 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 5 HP AT 240 VOLT AC 1-PHASE (28 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$ 136.46
Part #:INTMT103

24 HOUR TYPE STEEL MATERIAL 5-1/8 INCH WIDTH X 3-7/16 INCH DEPTH X 7-7/8 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR, SIGN, POOL HEATER, BLOWER, ELECTRIC FENCE, PUMP, FAN, CONVEYER, OTHER ELECTRICAL LOAD APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING NEMA 1 ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE), 1000 VOLT AMP AT 120 TO 277 VOLT AC (PILOT DUTY) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA), 5 HP AT 240 VOLT AC (28 FLA) 1-PHASE POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE DPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND MAXIMUM POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT DIMENSION (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BOTTOM) INCLUDES ON/OFF TRIPPER T100 MODEL
$ 133.50
Part #:INTMT101R

24 HOUR TYPE STEEL MATERIAL 5-1/2 INCH WIDTH X 3-5/8 INCH DEPTH X 9-3/8 INCH HEIGHT SIZE GRAY FINISH 1 TO 12 PER DAY MAX. NUMBER OF OPERATIONS 1 HOUR MIN. OFF TIME 1 HOUR MIN. ON TIME UL (CANADA AND US), CSA (CANADA AND US) APPROVAL INDOOR/OUTDOOR LIGHTING, POST LANTERN, SIGN, POOL HEATER, FILTER, HYDRO CHLORINATOR, AIR CONDITIONING, BLOWER, ELECTRIC FENCE, PUMP, HEATING/VENTILATING SYSTEM, MUSIC AND SIGNAL SYSTEM, FAN, POULTRY FOGGER, CONVEYER APPLICATION 125 VOLT AC AT 60 HERTZ VOLTAGE RATING ENCLOSURE MOUNTING NEMA 3R ENCLOSURE 40 AMP AT 120 TO 480 VOLT AC (RESISTIVE), 40 AMP AT 120 TO 277 VOLT AC (TUNGSTEN/INDUCTIVE) CURRENT RATING 2 HP AT 120 VOLT AC (24 FLA) POWER RATING -40 TO 130 DEG F OPERATING TEMPERATURE SPST SWITCH TYPE NO RESERVE POWER INTERMATIC BRAND INCLUDES ON/OFF TRIPPER POWER CONSUMPTION 3 WATT WIRE SIZE 14 TO 8 AWG KNOCKOUT SIZE (1) 1/2 INCH AND (1) 3/4 INCH (SIDE/BACK), (2) 1/2 INCH AND (2) 3/4 INCH (BACK) T100 MODEL
$ 165.84
Part #:CUTDH364UGK

HEAVY DUTY SAFETY TYPE 10 INCH LENGTH X 15.52 INCH WIDTH X 9.5 INCH HEIGHT SIZE PAINTED FINISH STEEL ENCLOSURE MATERIAL 3 WIRE(S) UL 98/50 APPROVAL NEMA 1 ENCLOSURE 200 AMP CURRENT RATING 15 HP AT 240 VOLT AC, 50 HP AT 480/600 VOLT AC 1-PHASE, 60 HP AT 240 VOLT AC, 125 HP AT 480 VOLT AC, 150 HP AT 600 VOLT AC 3-PHASE, 40 HP AT 250 VOLT DC POWER RATING 3 POLE(S) CARTRIDGE FUSE TYPE 480 TO 600 VOLT AC VOLTAGE RATING 250 VOLT DC VOLTAGE RATING NON-FUSIBLE FUSE PROVISION CUTLER-HAMMER BRAND INCLUDES NEUTRAL DH MODEL
Part #:CUTDH364NGK

HEAVY DUTY SAFETY TYPE 16 INCH WIDTH X 11.25 INCH DEPTH X 27.63 INCH HEIGHT SIZE PAINTED FINISH STEEL ENCLOSURE MATERIAL 4 WIRE(S) UL 98 APPROVAL NEMA 1 ENCLOSURE 200 AMP CURRENT RATING 50 HP AT 480/600 VOLT AC 1-PHASE, 125 HP AT 480 VOLT AC 3-PHASE, 150 HP AT 600 VOLT AC 3-PHASE (TIME DELAY FUSE) POWER RATING 3 POLE(S) CARTRIDGE, CLASS H, TIME DELAY FUSE TYPE SOLID NEUTRAL TYPE 480 VOLT AC STAR/277 VOLT AC, 600 VOLT AC STAR/347 VOLT AC AC VOLTAGE RATING 250 VOLT DC VOLTAGE RATING FUSIBLE FUSE PROVISION CUTLER-HAMMER BRAND DH MODEL
Part #:CUTDH364NRK

HEAVY DUTY SAFETY TYPE 30 INCH WIDTH X 18 INCH DEPTH X 9.5 INCH HEIGHT SIZE PAINTED GALVANIZED FINISH STEEL ENCLOSURE MATERIAL 4 WIRE(S) UL 98 APPROVAL NEMA 3R ENCLOSURE 200 AMP CURRENT RATING 50 HP AT 480/600 VOLT AC 1-PHASE, 125 HP AT 480 VOLT AC 3-PHASE, 150 HP AT 600 VOLT AC 3-PHASE (TIME DELAY FUSE) POWER RATING 3 POLE(S) CLASS H, TIME DELAY FUSE TYPE SOLID NEUTRAL TYPE 480 VOLT AC STAR/277 VOLT AC, 600 VOLT AC STAR/347 VOLT AC AC VOLTAGE RATING 250 VOLT DC VOLTAGE RATING FUSIBLE FUSE PROVISION CUTLER-HAMMER BRAND APPLICATION HEAVY COMMERCIAL, INDUSTRIAL, SERVICE ENTRANCE APPLICABLE STANDARD NEMA KS-1 DH MODEL
Part #:CUTDG224NGK

GENERAL DUTY SAFETY TYPE 3 WIRE(S) UL APPROVAL NEMA 1 ENCLOSURE 200 AMPERE CURRENT RATING 15 TO 25 HP AT 240 VAC 1 PHASE 50 HP AT 240 VAC 3 PHASE (DUAL ELEMENT FUSE) POWER RATING 2 POLE(S) CARTRIDGE CLASS H FUSE TYPE SOLID NEUTRAL TYPE 120/240 V AC VOLTAGE RATING FUSIBLE FUSE PROVISION APPLICABLE STANDARD NEMA KS-1 GROUNDED B PHASE SYSTEM APPLICATION DG MODEL
Part #:CUTUHTRS213BE

RINGLESS TYPE 11 INCH W X 4.38 INCH D X 15 INCH H SIZE 6 AWG TO 350 KCMIL (LINE/LOAD) WIRE SIZE UL APPROVAL 600 VAC VOLTAGE RATING SURFACE MOUNTING 200 AMPERE CURRENT RATING 1-PHASE 3-WIRE CIRCUIT CONFIGURATION OVERHEAD/UNDERGROUND SERVICE TYPE TRIPLEX GROUND NEUTRAL TYPE 3-5/16 INCH HUB OPENING HUB TYPE 4 JAW(S) HORN BYPASS SWITCH NUMBER OF SOCKETS 1 APPLICATION RESIDENTIAL, COMMERCIAL
$ 79.10
Part #:CUT3BR3042L200

MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 34-1/8 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (30) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL G1 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 435.89
 
Displaying: 1 - 17 of 17 Matching Items