Part #:CUTBR48L125SP

MAIN LUG TYPE 11 INCH W X 3-9/16 INCH D X 13 INCH H SIZE 8 MAX. NUMBER OF CIRCUITS (4) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING SURFACE WITHOUT DOOR COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL 7 ENCLOSURE SIZE DESIGNATION 14 TO 1/0 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 52.73
Part #:CUTBR612L125RP

MAIN LUG TYPE 11 INCH W X 3-9/16 INCH D X 13 INCH H SIZE 12 MAX. NUMBER OF CIRCUITS (6) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING NEMA 3R OUTDOOR RAIN PROOF ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL 7R ENCLOSURE SIZE DESIGNATION 14 TO 1 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 93.52
Part #:CUTBR612L125SP

MAIN LUG TYPE 11 INCH W X 3-9/16 INCH D X 13 INCH H SIZE 12 MAX. NUMBER OF CIRCUITS (6) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING SURFACE WITHOUT DOOR COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL 7 ENCLOSURE SIZE DESIGNATION 14 TO 1 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 58.49
Part #:CUTBR816L125SP

MAIN LUG TYPE 11 INCH W X 3-9/16 INCH D X 13 INCH H SIZE 16 MAX. NUMBER OF CIRCUITS (8) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING SURFACE WITHOUT DOOR COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL 7 ENCLOSURE SIZE DESIGNATION 14 TO 1 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 84.73
Part #:CUTEHD3050

MOLDED CASE, THERMAL MAGNETIC TYPE 4.13 INCH WIDTH X 3.38 INCH DEPTH X 6 INCH HEIGHT SIZE 480 VOLT MAX. AC VOLTAGE RATING 250 VOLT MAX. DC VOLTAGE RATING UL 489, CSA C22.2 APPROVAL 480 VOLT AC AT 50/60 HERTZ, 250 VOLT DC VOLTAGE RATING 14 KILOAMP AT 480 VOLT AC, 10 KILOAMP AT 250 VOLT DC INTERRUPTING RATING 50 AMP AT 40 DEG C CURRENT RATING 3 POLE(S) STANDARD PRESSURE LOAD TERMINAL TYPE FD FRAME TYPE CUTLER-HAMMER BRAND APPLICATION PANELBOARD, SWITCHBOARD, MOTOR CONTROL CENTER APPLICABLE STANDARD NEMA AB1, AS 2184, BS 4752, IEC 157-1, SABS 156, SEV 157-1, VDE 0660 C, EHD MODEL