No Feed-Thru Lugs
Power Distribution


Displaying: 1 - 8 of 8 Matching Items
8 Items
View:
Active Filters :
Part #:CUTAN16BN0AC

FULL VOLTAGE, NON-REVERSING TYPE NEMA 0 SIZE 18 AMP CURRENT RATING OPEN ENCLOSURE TYPE NEMA CONSTRUCTION STANDARD 110 VOLT AC AT 50 HERTZ, 120 VOLT AC AT 60 HERTZ COIL VOLTAGE 1NO AUXILIARY CONTACT 1 HP AT 115 VOLT 1-PHASE, 2 HP AT 230 VOLT 1-PHASE, 3 HP AT 208/240 VOLT 3-PHASE, 5 HP AT 380/480/600 VOLT 3-PHASE POWER RATING/VOLTAGE BI-METALLIC AMBIENT COMPENSATED OVERLOAD RELAY OVERLOADS 1 OR 3 PHASE CUTLER-HAMMER BRAND NUMBER OF POLES 3 MOUNTING TYPE HORIZONTAL APPROVAL UL, CSA FREEDOM, AN16 MODEL
$ 832.77
Part #:CUTAN16DN0AB

FULL VOLTAGE NON REVERSING TYPE NEMA 1 SIZE 27 AMPERE CURRENT RATING OPEN ENCLOSURE TYPE NEMA CONSTRUCTION STANDARD 110 VAC AT 50 HZ 120 VAC AT 60 HZ COIL VOLTAGE 1NO RIGHT MOUNT AUXILIARY CONTACT 2 HP AT 115 V 1 PHASE 3 HP AT 230 V 1 PHASE 7-1/2 HP AT 208/240 V 3 PHASE 10 HP AT 380 V 50 HZ/480/600 V 3 PHASE POWER RATING/VOLTAGE BIMETALLIC AMBIENT TEMPERATURE COMPENSATED 1NO-1NC AUTOMATIC/MANUAL RESET CLASS 10/20 OVERLOADS 1/3 PHASE APPROVAL UL CSA APPLICABLE STANDARD IEC 158 NEMA VDE BS NUMBER OF POLE 3 AN16 MODEL
$ 885.34
Part #:CUT3BR4242B200R

MAIN BREAKER TYPE 14-5/16 INCH W X 5-3/16 INCH D X 45 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING NEMA 3R OUTDOOR RAIN PROOF ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL CC MAIN BREAKER TYPE L2R ENCLOSURE SIZE DESIGNATION 1 AWG TO 250 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 1,631.77
Part #:CUT3BR4242B200

MAIN BREAKER TYPE 14-5/16 INCH W X 3-7/8 INCH D X 45 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL CC MAIN BREAKER TYPE L2 ENCLOSURE SIZE DESIGNATION 1 AWG TO 250 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 803.50
Part #:CUT3BR1224L200

MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 27 INCH H SIZE 24 MAX. NUMBER OF CIRCUITS (12) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL C4 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$627.00 MSRP $ 324.75
Part #:CUT3BR1836L150

MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 23 INCH H SIZE 36 MAX. NUMBER OF CIRCUITS (18) 1 INCH MAX. NUMBER OF SPACES UL APPROVAL 208 VAC STAR/120 VAC, 240 VAC VOLTAGE RATING 25 KILOAMPERE INTERRUPTING RATING 150 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1, INDOOR ENCLOSURE TYPE 3-PHASE 4-WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE TOP/BOTTOM FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL C2 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 303.51
Part #:CUT3BR3042L200

MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 34-1/8 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (30) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL G1 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 435.89
Part #:CUT3BR4242L200

MAIN LUG TYPE 14-5/16 INCH W X 3-7/8 INCH D X 39 INCH H SIZE 42 MAX. NUMBER OF CIRCUITS (42) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 208 VAC STAR/120 VAC 240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 200 AMPERE CURRENT RATING FLUSH/SURFACE COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 3 PHASE 4 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL L1 ENCLOSURE SIZE DESIGNATION 1 AWG TO 300 KCMIL (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 645.96
 
Displaying: 1 - 8 of 8 Matching Items