Part #:CUTBR48L125SP

MAIN LUG TYPE 11 INCH W X 3-9/16 INCH D X 13 INCH H SIZE 8 MAX. NUMBER OF CIRCUITS (4) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING SURFACE WITHOUT DOOR COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL 7 ENCLOSURE SIZE DESIGNATION 14 TO 1/0 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 52.73
Part #:CUTBR612L125RP

MAIN LUG TYPE 11 INCH W X 3-9/16 INCH D X 13 INCH H SIZE 12 MAX. NUMBER OF CIRCUITS (6) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING NEMA 3R OUTDOOR RAIN PROOF ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL 7R ENCLOSURE SIZE DESIGNATION 14 TO 1 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 93.52
Part #:CUTBR612L125SP

MAIN LUG TYPE 11 INCH W X 3-9/16 INCH D X 13 INCH H SIZE 12 MAX. NUMBER OF CIRCUITS (6) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING SURFACE WITHOUT DOOR COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL 7 ENCLOSURE SIZE DESIGNATION 14 TO 1 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 58.49
Part #:CUTBR816L125SP

MAIN LUG TYPE 11 INCH W X 3-9/16 INCH D X 13 INCH H SIZE 16 MAX. NUMBER OF CIRCUITS (8) 1 INCH MAX. NUMBER OF SPACES UL 50 UL 67 UL 489 UL 869 APPROVAL 120/240 VAC VOLTAGE RATING 10000 AMPERE INTERRUPTING RATING 125 AMPERE CURRENT RATING SURFACE WITHOUT DOOR COVER TYPE NEMA 1 INDOOR ENCLOSURE TYPE 1 PHASE 3 WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE NEUTRAL TYPE BOTTOM/TOP FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL 7 ENCLOSURE SIZE DESIGNATION 14 TO 1 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC BR MODEL
$ 84.73
Part #:CUTBRP10B100RF

MAIN BREAKER TYPE 14-5/16 INCH W X 5-3/16 INCH D X 18-3/4 INCH H SIZE 20 MAX. NUMBER OF CIRCUITS (10) 1 INCH MAX. NUMBER OF SPACES UL APPROVAL 120/240 VAC VOLTAGE RATING 10 KILOAMPERE INTERRUPTING RATING 100 AMPERE CURRENT RATING NEMA 3R, OUTDOOR, RAINPROOF ENCLOSURE TYPE 1-PHASE 3-WIRE CIRCUIT CONFIGURATION INSULATED/BONDABLE SPLIT NEUTRAL TYPE TOP/BOTTOM FEED LOCATION TIN PLATED ALUMINUM BUS MATERIAL BR MAIN BREAKER TYPE B2R ENCLOSURE SIZE DESIGNATION 4 TO 1/0 AWG (ALUMINUM/COPPER) MAIN WIRE SIZE APPLICABLE STANDARD NEC INCLUDES FEED THROUGH LUG FOR PHASE/NEUTRAL CONDUCTOR BR MODEL
$ 199.82
 